Alarm setting range 

Deviation value 

Alarm action

Alarm action hysteresis 

Alarm output/rating 

Heater Break Alarm (option)

This function can be added if the instrument has an alarm option and the control output is the contact type or the SSR drive voltage type. In SR71,
addition is possible unless it has an SV bias option.

Alarm action 

Current setting range 

Setting resolution 

Amperage display 

Display acuuracy 

Minimum time for action confirmation 

Alarm holding 

Sampling cycle 

Isolation 

Set value Bias (option)

In SR71,this function can be added unless it has a Heater Break Alarm option.

Setting range 

Setting resolution 

Action input 

Isolation 

Others

Data storage

Operating ambient temperature

/humidity range 

Supply voltage 

Power consumption 

Applicable standard Safety 

EMC  EMI (emission) 

EMS (immunity) 

Insulation resistance 

Dielectric strength 

Protective structure 

Material 

External dimensions 

SR71 

SR72 
SR73 
SR74 

Mounting 

Panel thickness 

Panel cutout 

SR71 

SR73 

Weight SR71 

SR73

-

16 -

: Higher limit and lower limit absolute value alarms: Within full scale of measuring range
: Higher limit: 0~2000 unit

Lower limit: –1999~0 unit
In case SV is out of the measuring range, higher and lower limit values of the measuring range become the
action points.

: On-Off action
: Fixed to 0.2% of the measuring range
: Contact 1a (common)/240V AV 1.5A (resistive load)

: Heater amperage detected by externally attached CT. Alarm output

On upon detection of heater break while control output is On.

: Off, 0.1~50.0A (Alarm action stops when Off is set.)
: 0.1A
: 0.0~55.0A
: 5% FS (when sine wave is 50Hz)
: On time:500 msec.
: Selectable between Lock (holding) and Real (not holding)
: 2 sec.
: Insulated between CT input and control output (not isolated between CT input and system and other 

inputs)

: –1999~2000 unit
: Same as display resolution
: Non-voltage contact (bias in action when SB terminal is closed)
: Insulated between the SV bias input and the control output (not isolated between the SV bias and the 

system and other input)

: By non-volatile memory (EEPROM)
: –10~50˚C/90% RH max. (no dew condensation)

: 100-240V AC±10% (50/60 Hz)
: Approx. 11VA
: IEC1010-1
: EN50081-1
: EN50082-2
: Between input/output terminal and power supply terminal:

500V DC 20M

minimum

Between input/output terminal and protective conductor terminal:
500V DC 20M

minimum

: 1 min. at 2300V AC between input/output terminal and power supply terminal

1 min. at 1500V AC between power supply terminal and protective conductor terminal

: Only front panel has simple dust-proof and drip-proof structure
: PPO resin molding (equivalent to UL94V-1)
: H48

×

W48

×

D110 (panel depth:100) mm

: H72

×

W72

×

D110 (panel depth:100) mm

: H96

×

W96

×

D110 (panel depth:100) mm

: H96

×

W48

×

D110 (panel depth:100) mm

: Push-in panel (one-touch mount)
: 1.0~3.5 mm
: H45

×

W45 mm, SR72: H68

×

W68 mm

: H92

×

W92 mm, SR74: H92

×

W45 mm

: Approx.180g, SR72: Approx.260g
: Approx.330g, SR74: Approx.250g

T 0012200
PRINTED IN JAPAN

The contents of this manual are subject to change without notice.

Содержание SR70 Series

Страница 1: ...ties additional instructions are indicated by the following headings WARNING Exercise extreme caution as indicated This heading indicates hazardous conditions that could cause injury or death of perso...

Страница 2: ...ge 23 The output terminal should be connected with a device which meets the requirements of IEC1010 A voltage current different from that of the input specification should not be added on the input te...

Страница 3: ...resentative or our local office concerning any problems with the product accessories or related items 1 2 Caution for use 1 Avoid operating keys of the front panel with hard or sharp objects or motion...

Страница 4: ...se and rotate the screwdriver while pushing up the lock lever behind the packing Once the instrument comes out by a few millimeters you can remove it by hand 2 4 External dimensions and panel cutout S...

Страница 5: ...nal Recommendable noise filter TDK ZMB2203 13 Name of terminal and description Power terminal 100 240V AC 10 50 60Hz 11VA Protective conductor terminal Input terminal R T D A Thermocouple Voltage Curr...

Страница 6: ...3 AH alarm output monitor LED red Turns on for higher limit alarm output ON 4 AL HB alarm output monitor LED red Turns on for lower alarm output ON or heater break alarm ON Key switches 1 parameter ke...

Страница 7: ...econds on basic screen of the mode 0 screen group to change the screen into mode 2 screen Keep pressing key for five 5 seconds on the mode 2 screen to change screen into basic screen of the mode 0 scr...

Страница 8: ...ssed the flashing decimal point in the rightmost digit moves from the top row bottom row top and bottom rows top row In case the lower limit value and the higher limit value are set to produce a diffe...

Страница 9: ...action mode select digit Initial value Select from Lock mode and REAL mode Refer to 5 3 3 Input scaling screen Initial value Lower limit value top row 0 0 Higher limit value bottom row 100 0 Position...

Страница 10: ...20 21 22 39 40 41 42 43 44 45 46 Measuring range F 0 3300 0 3100 0 3100 150 750 0 2200 0 1300 0 1100 300 400 0 2300 300 400 0 1100 300 1100 150 0 200 0 50 0 120 0 0 400 300 1100 150 0 200 0 50 0 120...

Страница 11: ...in the following condition during AT execution Duration equal to or longer than 2 hours passed in the output level of 0 or 100 Power shutdown PV measured value is over the scale during AT execution 5...

Страница 12: ...s selected Lower limit deviation value alarm is output for measured value to be less than set value alarm set value For lower limit deviation value alarm if set value alarm set value is less than the...

Страница 13: ...ade for longer than three 3 minutes on each screen except heater break alarm value set screen the screen moves back to the basic screen of the mode 0 screen group auto return 6 2 PID Screen No 2 4 and...

Страница 14: ...B and multiple break of A B B upon R T D input 2 Defect of heater break alarm CT CT input value is greater than 55A CT input value is less than 5A NOTE Message of heater break alarm is only displayed...

Страница 15: ...C to the negative side of measuring range in case of T and U input though JIS Pt100 Jpt100 3 wire type Approx 0 25mA 5 max wire The 3 lead wires should have same resistance 0 10 10 50 0 100mV DC or 0...

Страница 16: ...ge detected by externally attached CT Alarm output On upon detection of heater break while control output is On Off 0 1 50 0A Alarm action stops when Off is set 0 1A 0 0 55 0A 5 FS when sine wave is 5...

Отзывы: