4-5. Measuring range code table

5. Operation

5-1. Setting of set value (SV)

(1) Set value setting is performed on basic screen of the mode 0 screen group.

(2) Press the 

or 

key to set set value. Keep pressing it to flash the point of the least digit of set value and increase (or decrease) value.

(3) After confirming the value to coincide the set value, press 

to register the data.

(4) After registration of the data, the point of the least digit goes off.

Example: Setting set value to 500˚C

4-6. Alarm type code table

NOTE: The inhibit action on the alarm type code table above is the action which outputs alarm when the measured value enters

alarming range again after inhibiting alarm output for the value within the alarming range and allows it out of the range once.

Input type

Code

01
02
03
04
05
06
07
08
09
10
11
31
32
33
34
35
36
37
38
71
72
73
81
82
83
95

Multi input

Thermocouple

R.T.D.

Voltage mV

Voltage V

Current 4

~

20mA

*1B

R

S

K
K

E

J

T

N

*2U

*2L

Measuring range  (˚C)

0

~ 1800

0

~ 1700

0

~ 1700

100

~ 400

0

~ 1200

0

~ 700

0

~ 600

199.9 ~ 200.0

0

~ 1300

199.9 ~ 200.0

0

~ 600

200

~ 600

100.0 ~ 100.0

50.0 ~

50.0

0.0 ~ 200.0

200

~ 600

100.0 ~ 100.0

50.0 ~

50.0

0.0 ~ 200.0

Initial value: 0.0 ~ 100.0
Conditions of scaling
Scaling setting range:

1999~9999,

Span: 10~5000 counts
Position of decimal point:
No decimal point, the first second
and third decimal places

Code

12
13
14
15
16
17
18
19
20
21
22
39
40
41
42
43
44
45
46

Measuring range  (˚F)

0

~ 3300

0

~ 3100

0

~ 3100

150

~ 750

0

~ 2200

0

~ 1300

0

~ 1100

300

~ 400

0

~ 2300

300

~ 400

0

~ 1100

300

~ 1100

150.0 ~ 200.0

50.0 ~ 120.0

0

~ 400

300

~ 1100

150.0 ~ 200.0

50.0 ~ 120.0

0

~ 400

*1  Thermocouple B: Accuracy not guaranteed 

for temperatures below 400˚C (750˚F).

*2  Thermocouple U,L: DIN43710

Thermocouple B,R,S,K,E,J,T,N:
JIS/ANSI/IEC
R.T.D.Pt100: Present JIS/IEC
JPt100: FormerJIS

Alarm code

0    (

)

1    (

)

2    (

)

3    (

)

4    (

)

5    (

)

6    (

)

7    (

)

8    (

)

AH assignment

With/Without inhibit

action

AL/HB assignment

Not assigned

Higher limit deviation

value

Higher limit absolute

value

Higher limit deviation

value

Higher limit absolute

value

Higher limit deviation

value

Higher limit absolute

value

Higher limit deviation

value

Higher limit absolute

value

Without inhibit action

Without inhibit action

With inhibit action

With inhibit action

Without inhibit action

Without inhibit action

With inhibit action

With inhibit action

Not assigned

Lower limit deviation

value

Lower limit absolute

value

Lower limit deviation

value

Lower limit absolute

value

Heater break

Heater break

Heater break

Heater break

With/Without inhibit

action

Without inhibit action

Without inhibit action

With inhibit action

With inhibit action

0-0 basic screen

one by one

continuing

point flashing

point flashing

point goes off to
indicate registration

key

key

key

Pt100

JPt100

0

~

10

10

~

50

0

~

100

0

~

1

1

~

5

0

~

10

NOTE: In case types of Alarms are changed, values are intialized.

NOTE: In case measuring

 range

 is modified, set values, alarm action point and other related values are all initialized.

Содержание SR70 Series

Страница 1: ...ties additional instructions are indicated by the following headings WARNING Exercise extreme caution as indicated This heading indicates hazardous conditions that could cause injury or death of perso...

Страница 2: ...ge 23 The output terminal should be connected with a device which meets the requirements of IEC1010 A voltage current different from that of the input specification should not be added on the input te...

Страница 3: ...resentative or our local office concerning any problems with the product accessories or related items 1 2 Caution for use 1 Avoid operating keys of the front panel with hard or sharp objects or motion...

Страница 4: ...se and rotate the screwdriver while pushing up the lock lever behind the packing Once the instrument comes out by a few millimeters you can remove it by hand 2 4 External dimensions and panel cutout S...

Страница 5: ...nal Recommendable noise filter TDK ZMB2203 13 Name of terminal and description Power terminal 100 240V AC 10 50 60Hz 11VA Protective conductor terminal Input terminal R T D A Thermocouple Voltage Curr...

Страница 6: ...3 AH alarm output monitor LED red Turns on for higher limit alarm output ON 4 AL HB alarm output monitor LED red Turns on for lower alarm output ON or heater break alarm ON Key switches 1 parameter ke...

Страница 7: ...econds on basic screen of the mode 0 screen group to change the screen into mode 2 screen Keep pressing key for five 5 seconds on the mode 2 screen to change screen into basic screen of the mode 0 scr...

Страница 8: ...ssed the flashing decimal point in the rightmost digit moves from the top row bottom row top and bottom rows top row In case the lower limit value and the higher limit value are set to produce a diffe...

Страница 9: ...action mode select digit Initial value Select from Lock mode and REAL mode Refer to 5 3 3 Input scaling screen Initial value Lower limit value top row 0 0 Higher limit value bottom row 100 0 Position...

Страница 10: ...20 21 22 39 40 41 42 43 44 45 46 Measuring range F 0 3300 0 3100 0 3100 150 750 0 2200 0 1300 0 1100 300 400 0 2300 300 400 0 1100 300 1100 150 0 200 0 50 0 120 0 0 400 300 1100 150 0 200 0 50 0 120...

Страница 11: ...in the following condition during AT execution Duration equal to or longer than 2 hours passed in the output level of 0 or 100 Power shutdown PV measured value is over the scale during AT execution 5...

Страница 12: ...s selected Lower limit deviation value alarm is output for measured value to be less than set value alarm set value For lower limit deviation value alarm if set value alarm set value is less than the...

Страница 13: ...ade for longer than three 3 minutes on each screen except heater break alarm value set screen the screen moves back to the basic screen of the mode 0 screen group auto return 6 2 PID Screen No 2 4 and...

Страница 14: ...B and multiple break of A B B upon R T D input 2 Defect of heater break alarm CT CT input value is greater than 55A CT input value is less than 5A NOTE Message of heater break alarm is only displayed...

Страница 15: ...C to the negative side of measuring range in case of T and U input though JIS Pt100 Jpt100 3 wire type Approx 0 25mA 5 max wire The 3 lead wires should have same resistance 0 10 10 50 0 100mV DC or 0...

Страница 16: ...ge detected by externally attached CT Alarm output On upon detection of heater break while control output is On Off 0 1 50 0A Alarm action stops when Off is set 0 1A 0 0 55 0A 5 FS when sine wave is 5...

Отзывы: