5
2. Introduction of Shihlin Inverter
Introduction of Inverter
2.1 Electric specification
2.1.1 220V Series Single-Phase
Model SE2-021-
□□□
K
0.4K
0.75K
1.5K
2.2K
applicable motor capacity
HP
0.5
1
2
3
kW
0.4
0.75
1.5
2.2
Output
Rated output capacity kVA (Note)
1.2
1.9
3.0
4.2
Rated output current A (Note)
3.0
5.0
8.0
11.0
Over-current capability
150% 60 seconds; 200% 1 second (reverse time
characteristics)
Maximum output voltage
3 Phase 200~240V AC
Power
supply
Rated power voltage
single phase 200~240V 50Hz / 60Hz
Power voltage permissible
fluctuation
single phase 180~264V 50Hz / 60Hz
Power frequency permissible
fluctuation
±5%
Power source capacity kVA
1.8
3
4.5
6.4
Cooling method
Nature cooling
Forced air cooling
Weight kg
1.2
1.2
1.9
1.9
2.1.2 220V Series Three-Phase
Model SE2-023-
□□□
K
0.4K
0.75K
1.5K 2.2K
3.7K
5.5K 7.5K
applicable motor
capacity
HP
0.5
1
2
3
5
7
10
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
Output
Rated output capacity kVA (Note)
1.2
1.9
3.0
4.2
6.7
9.2
12.6
Rated output current A (Note)
3.0
5.0
8.0
11.0
17.5
24
33
Over-current capability
150% 60 seconds; 200% 1 second (reverse time
characteristics)
Maximum output voltage
3 Phase 200~240V AC
Power
supply
Rated power voltage
3 Phase 200~240V 50Hz / 60Hz
Power voltage permissible
fluctuation
3 Phase 170~264V 50Hz / 60Hz
Power frequency permissible
fluctuation
±5%
Power source capacity kVA
1.8
3
4.5
6.4
10
13.8
19
Cooling method
Nature
cooling
Forced air cooling
Weight kg
1.2
1.2
1.2
1.9
1.9
3.8
3.8