136
Appendix 1 Parameter list
Parameter list
Parameter
number
Name
Setting range
Minimum
setting unit
Default value
User setting
value
Reference
page
P.197
Frequency corresponds to the
maximum input currentvoltage
across terminal 4-5
0~400Hz
0.01Hz
50Hz/60Hz
(注
2
)
P110
P.198
Minimum input current/voltage
across terminal 4-5
0~20
0.01
0
P110
P.199
Maximum input current/voltage
across terminal 4-5
0~20
0.01
0
P110
P.229
Backlash compensation
function selection
0~1
1
0
P111
P.230
The backlash compensation
acceleration interrupt frequency
0~400Hz
0.01Hz
1Hz
P111
P.231
The backlash compensation
acceleration interrupt time
0~360s
0.1s
0.5s
P111
P.232
The backlash compensation
deceleration interrupt frequency
0~400Hz
0.01Hz
1Hz
P111
P.233
The backlash compensation
deceleration interrupt time
0~360 s
0.1s
0.5s
P111
P.234
Triangular wave function
selection
0~2
1
0
P112
P.235 Maximum amplitude
0~25%
0.1%
10%
P112
P.236
Amplitude compensation for
deceleration
0~50%
0.1%
10%
P112
P.237
Amplitude compensation for
acceleration
0~50%
0.1%
10%
P112
P.238 Amplitude acceleration time
0~360s
/0~3600 s
0.01 s/0.1s
10 s
P112
P.239 Amplitude deceleration time
0~360s
/0~3600 s
0.01 s/0.1s
10s
P112
P.240
Auxiliary frequency function
selection
0~4
1
0
P113
P.242
DC injection brake function
before starting selection
0~1
1
0
P114
P.243
DC injection brake time before
starting
0~60s
0.1s
0.5s
P114
P.244
DC injection brake voltage
before starting
0~30%
0.1%
4%
P114
P.247 MC switch interlock time
0.1~100s
0.1s
1s
P114
P.248 Start waiting time
0.1~100s
0.1s
0.5s
P114