Appendix 1 Parameter list
Parameter List
160
Parameter
number
Name
Setting range
Minimum
setting unit
Default value
User
setting
value
Reference
page
P.258
S pattern time at the end of
deceleration
0~25s,9999
0.01s/0.1s
9999
P58
P.259 Speed unit selection
0, 1
1
1
P80
P.260 Over torque detection selection
0, 1
1
1
P114
P.261 Maintenance Alarm Time
0~9998day
1
0
P136
P.286
High frequency vibration
inhibition factor
0~15
1
0
P136
P.287
Short circuit protection function
selection
0~1
1
1
P137
P.288
Alarm code display option
0~12
1
0
P137
P.289
Alarm code
---
---
0
P137
P.290
The latest alarm status selection
0~6
1
0
P137
P.291
The latest alarm message
---
---
0
P137
P.292
Accumulative motor operation
time (minutes)
0~1439min
1min
0 min
P138
P.293
Accumulative motor operation
time (days)
0~9998day
1day
0 day
P138
P.294 Decryption parameter
0~9998
1
0
P138
P.295 Password setup
2~9998
1
0
P138
P.300 Motor control mode selection
0~2
1
0
P139
P.301
Motor parameter auto-tuning
function selection
0~3
1
0
P139
P.302 Motor rated power
0~160
0.01
0
P141
P.303 Motor poles
0~8
1
4
P141
P.304
Motor rated voltage
0~440V
1 V
220/440V
P141
P.305
Motor rated frequency
0~650Hz
0.01Hz
50Hz/60Hz
(
Note
)
P141
P.306 Motor rated current
0~500A
0.01 A
Horsepower-based
P141
P.307 Motor rated rotation speed
0~9998
r/min
1 r/min
1410/1710 r/min
(
Note
)
P141
Содержание SS2 Series
Страница 21: ...Introduction of Shihlin Inverter Introduction of Inverter 17 3 5 5 System wire arrangement ...
Страница 174: ...Appendix 6 European Specification Compatibility Description Specification Description 170 CE Certification Statement ...
Страница 175: ...Appendix 6 European Specification Compatibility Description Specification Description 171 ...