11
Operation
Operation
To turn on the heater
1 . Turn on the valve on the gas supply cylinder .
2 . Press and turn the variable control knob to PILOT position
(counter clockwise 90˚).
3 . Press down the variable control knob and hold for 30 seconds .
While holding down the variable control knob, press the igniter
button several times until the pilot flame ignites. Release the
variable control knob 20-30 seconds after the ignition .
4 . Turn the variable control knob to LO and leave it there for 5 minutes or more before
turning the knob to desired temperature setting .
5 .
If the burner flame goes out accidentally or it is blown out by wind, turn off the heater
and wait at least 5 minutes or more to let the gas disperse before re-lighting to avoid
possible gas explosion . Repeat steps 2 to 4 .
Note
• If a new tank has just been connected, please allow at least one minute for the air in the
gas pipeline to release through the pilot hole, or simply continue with step 3 .
•
When lighting the pilot flame make sure that the variable control knob is continuously
depressed while pressing the igniter button .
•
Variable control knob can be released after the pilot flame is lit for 20-30 seconds.
•
Pilot flame can be watched and checked from the peephole located on the base of burner.
•
If the pilot flame does not light or it goes out, repeat step 3.
To turn off the heater
1 . Turn the variable control knob to PILOT position .
2 . Press and turn the variable control knob to OFF position .
3 . Turn off the valve of the gas cylinder and disconnect the cylinder
Warning
FOR YOUR SAFETY:
•
DO NOT touch or move heater for at least
45 minutes after use .
•
Allow all burner elements to cool before
Touching .
NOTE
•
In a salt-air environment (such as near an
Ocean) corrosion occurs more quickly
than normal .
•
Wait until heater is cool before covering .