Gas Requirements
Gas Requirements
•
Use propane or LPG only .
•
The heater is designed for use with 11-13 kg cylinder . Maximum size of cylinder
suitable for the appliance, w/ regulator attached, is Æ31 cm x 64 cm . Inner
dimension of stand within the supporting bars is Æ32 cm x 69 cm .
•
The appliance requires approved gas hose in 60 cm length and a regulator, or a gas
hose in 140 cm length and a regulator if no gas pipe (approx . 84 cm) is used .
•
Regulator maximum inlet pressure must not exceed 690 kPa (100 PSI) .
•
Regulator outlet pressure to be 37 mbar .
•
The hose and regulator assembly must conform to local standard codes .
•
The installation must conform to local codes, or in the absence of local codes, to the
standard for the storage and handling of liquid petroleum gases .
•
A dented, rusted or damaged gas cylinder may be hazardous and should be checked
by your gas supplier . Never use a gas cylinder with a damaged valve connection .
•
The gas cylinder must be arranged to provide for vapor withdrawal from the
operating cylinder .
•
Avoid twisting the flexible tubes and hoses.
•
Never connect an unregulated gas cylinder to the heater .
•
Disconnect the gas cylinder when the heater is not use .