4
Location
Location
The appliance is for outdoor use only.
• Do not use the heater indoors or in an enclosed area . Always ensure that adequate air
ventilation is provided .
• Do not use the heater in a basement or below ground level .
• This appliance should only be used in an above ground open-air environment with
natural ventilation, where gas leakage or combustible materials are dispersed .
• Any enclosure in which the appliance is used should comply with one of the following:
• Within a partial enclosure that includes an overhead cover and more than
two walls, the following shall apply:
• At least 25% of the total wall area is completely open and at least 30% of
the remaining wall area is open and unrestricted .
• If being used on a balcony area, at least 20% of the total wall area should
remain open and unrestricted .
This appliance should only be used in an outdoor area and should not be used in a
building, garage or any other enclosed area.
Technical Specifications
Nominal HEAT INPUT 13 kW (450 g/hr – 870 g/hr)
Appliance Category
I3+
I3B/P
I3B/P
I3B/P
Gas Reference
G30/G31
G30/G31
G30/G31
G30/G31
Normal Gas Pressure
28-30/37 mbar 28-30 mbar
30 mbar
50 mbar
Burner Injector
1 .9mm
1 .9mm
1 .9mm
1 .8mm
FOR USE OUTDOORS ONLY
Use propane only . Burner pressure: 37 mbar - Burner injector: 1 .9 mm - Pilot injector: 0 .20 mm
Close the valve of the gas cylinder or the regulator after use . The use of this appliance in closed
areas can be dangerous and is PROHIBITED . Read the instructions before using this appliance .
The appliance must be installed in accordance with the instructions and local regulations .
Metal w/ powder coating 18 kg . Stainless Steel 17 kgs . Height: 2250 mm