9-3
MINOR TROUBLES & SOLUTIONS
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY
Saw blade motor does not run
even though blade drive button
is pressed.
Overload relay activated
Reset
Saw blade is not at forward
limit position.
Press SAW FRAME
FORWARD button
MOTOR TROUBLES & SOLUTIONS
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY
Motor will not start
Magnetic switch open, or
protector open.
Reset protector by pushing red button (inside
electric box.)
Low voltage
Check power line for proper voltage.
Open circuit in motor or loose
connections.
Inspect all lead terminations on motor for loose
or open connections.
Motor will not start,
fuse or circuit
breakers “blow”.
Short circuit in line, cord or
plug.
Inspect line, cord and plug for damaged
insulation and shorted wire.
Short circuit in motor or loose
connections
Inspect all lead terminations on motor for loose
or shorted terminals or worn insulation on
wires.
Incorrect fuses or circuit
breakers in power line.
Install correct fuses or circuit breakers.
Motor fail to develop
full power. (Power
output of motor
decreases rapidly
with decrease in
voltage at motor
terminals.)
Power line overloaded with
lights, appliances and other
motors.
Reduce the load on the power line.
Undersize wires or circuit too
long.
Increase wire sizes, or reduce length of wiring
General overloading of power
company‘s facilities.
Request a voltage check from the power
company
Motor overheat
Motor overloaded.
Reduce load on motor
Air circulation through the
motor restricted.
Clean out motor to provide normal air
circulation through motor.
Motor stalls
(Resulting in blown
fuses or tripped
circuit breakers)
Short circuit in motor or loose
connections.
Inspect terminals in motor for loose or shorted
terminals or worn insulation on lead wires.
Low voltage
Correct the low line voltage conditions.
Incorrect fuses or circuit
breakers in power line.
Install correct fuses circuit breakers.
Motor overloaded
Reduce motor load.
Frequent opening of
fuses or circuit
breakers.
Motor overloaded
Reduce motor load
Incorrect fuses or circuit
breakers.
Install correct fuses or circuit breakers.
Содержание SW-180NC
Страница 1: ...SW 180NC Instruction Manual Version 1 20180619 ...
Страница 2: ......
Страница 8: ......
Страница 13: ...1 5 Illustration Emergency Stop Emergency Stop ...
Страница 15: ...1 7 Illustration Safety Labels SW 180NC SafetyLabels ...
Страница 20: ...2 4 FLOOR PLAN Machine top view ...
Страница 21: ...2 5 Machine front view Machine side view ...
Страница 22: ......
Страница 66: ......
Страница 67: ...6 1 Section 5 ELECTRICAL SYSTEM ELECTRICAL DIAGRAMS ...
Страница 68: ......
Страница 69: ...SW 180NC CONTROL PANEL LAYOUT ...
Страница 70: ...SW 180NC CIRCUIT BOARD LAYOUT ...
Страница 71: ...SW 180NC POWER SUPPLY LAYOUT ...
Страница 72: ...SW 180NC PLC INPUT OUTPUT LAYOUT ...
Страница 73: ...6 1 Section 6 HYDRAULIC SYSTEM HYDRAULIC DIAGRAMS ...
Страница 74: ...SW 180NC Hydraulic Circuit 2015 03 23 ...
Страница 75: ...7 1 Section 7 BANDSAW CUTTING A PRACTICAL GUIDE INTRODUCTION SAW BLADE SELECTION VISE LOADING BladeBreak In ...
Страница 96: ......
Страница 97: ...TOTAL ASSEMBLY 10_2 SW 180NC ...
Страница 98: ...3 9 10 16 13 15 12 8 7 11 4 5 1 2 17 6 18 20 21 19 14 Base assembly 10_3 SW 180NC ...
Страница 104: ...13 14 18 19 7 10 17 9 3 11 2 1 4 8 15 12 5 6 16 C470H 20000固定床面組 10_9 SW 180NC ...
Страница 106: ...22 6 1 27 8 16 26 10 30 24 23 19 25 28 5 18 2 31 7 9 4 17 29 13 11 15 21 14 20 12 3 32 C470H 20000送料床面組 10_11 SW 180NC ...
Страница 114: ...4 16 1 15 8 10 7 6 3 5 13 12 11 2 14 17 9 C470H 31000 鋸臂組 Saw arm assembly 10_19 SW 180NC ...
Страница 123: ......
Страница 124: ......
Страница 125: ......
Страница 126: ......