Confidential
For use by Sharp authorized dealers
and distributors only.
Not for general distribution.
PN-HB851/HB751/HB651/HM851/HM751/HM651 Installation Guidelines <Rev1.0> April. 2019
6
Space requirement
Securing space at the Top/ Bottom/ Left/ Right/ Behind/
Surface of the monitor is necessary regardless of wall-
hanging or stand type installation.
Landscape /
Portrait Installation
Horizontal
Installation
(Only faceup)
Top
20.0cm
20.0cm
Bottom
5.0cm
20.0cm
Side
5.0cm
20.0cm
Behind
3.5cm
20.0cm
Surrounding
temperature
0
~
40
℃
0
~
30
℃
*
this figures are without outer casing.
If you install with outer casing, requirements are changed by size/location of vent
hole, whether or not fan.
The effectiveness of each measure differs depending on the
environment. Please choose the best measure for respective
environment as follow.
- Adding a cooling fan(please use the filter and clean it regularly.)
- Improve the ventilation by widening its space
- Adding a heat exchanger
Heat prevention unit
(Apiste co.)
Example of fan installation
- If the temperature is too high
Electronic component’s
life time will be shortened or break down.
-If the temperature on LCD surface is too high
Monitors will break down or uniformity issue will occur
- If the temperature is too low
Monitors will break down,
will not launch or monitor issue will occur.
The thermal influence
Temperature control and clearance space
conditions
- Usable temperature range
※
1
→
0
℃
-40
℃
(
Horizontal Installation
:
0
~
30
℃
)
- Temperature of LCD surface
→
Under
60
℃
Please follow these requirements when setting the
monitor. Refer to them and install the monitor according
to its requirements.
※
1: this range may change by requirements.
2.1 Precautions for temperature and clearance space