PN-HB851/HB751/HB651/HM851/HM751/HM651 Installation Guidelines <Rev1.0> April. 2019
・
Ambient temperature must be below 30
℃
(Place with working air conditioned).
※
If securing the space is
difficult, and the ambient temperature exceed 30
℃
, please install a cooling system such as fan to ensure
that the ambient temperature is 0
℃
~ 30
℃
・
Please secure space more than 20 cm from wall and floor in order to flow air smoothly.
・
If monitors are overlaid with protection panel, the temperature of the space between monitor surface and
protection panel must be kept under 40
℃
with cooling system.
・
The protection panel may transform and curves inward by heat depending on its material, therefore please
adjust a necessary space between monitor and protection panel based on the flexure of protection panel,
load from upper part, and the installation method. Please be sure that
protection panel do not touch the
monitor surface
even if it is curved.
・
Do not press the monitor surface and drop anything on the monitor surface.
・
Please be careful not to nip cables between monitor and mounting bracket.
・
Remove handles and support the monitor by the portions where handles used to be. (Do not use mount
screw holes to support the monitor.)
Face-Up installation
Floor
19
Support the monitor
by handle portion
Support the monitor
by handle portion
Handle
Air flow
Air flow
Secure space
more than
20 cm
Secure space
more than
20 cm
Secure space
more than
20 cm
Secure space between
protection panel and
monitor surface
Wall
Wall
2.11 Precautions for orientation 3