PN-HB851/HB751/HB651/HM851/HM751/HM651 Installation Guidelines <Rev1.0> April. 2019
• This model is only for internal use. Please avoid weather and direct sunlight when installing. They cause breakdown
and degradation.
• Humidity condition for IDP
• Range of humidity condition for IDP :
From 20% to 80%(no condensation)
• Dew condensation and/or liquid drops will cause the breakdown of the circuit
and/or LCD panel. Please install LCD away from condensation and liquid drops.
• About dew condensation
The back cabinet of the product is plate. So dew condensation occurs easily.
The environment which has high possibility of condensation
• Place where temperature is generally low but has frequent warm air flow.
(Example : the place in front of the vents of radiators. When the radiator is turn on in a cold winter morning,
condensation occurs.)
• Near the sea, lake, mountain and so on where humidity is high
• The environment which has high possibility of water drops
• “Semi-outdoor” place where strong winded-rain(typhoon) could potentially reach the monitor. The place which is
below the pipes inside the ceiling. (When installing in these places, countermeasures should be taken to avoid
water drops to reach the monitors. For example, covering the LCD monitor with box. In such a case, consideration
should be given for direction of vent.)
• Caution for the wind of the typhoon
• Please install so that you can remove the influence from the wind.
• Caution for salt damage
• Please hold counsel with us in advance when installing near the sea where salt damage may occur.
• Caution for sulfide
• Please don’t install near the hot spring and volcano where there may occur the influence from sulfide.
• Caution for organic gas and flammable gas
• Please don’t install the place where there may be organic gas and flammable gas.
10
About installation location, dew condensation, water drops and salt damage
Air-breathing
from below
Exhausting the
air to back
2.5 Precautions for installation location,