1.14. Dehumidifying operation control
In the Dehumidifying mode, the temperature setting is automatically
determined based on the outside air temperature. In addition, the air
conditioner operation differs from the operation in the Manual mode as
explained below.
1.15. Full power Operation
In this operation, the air conditioner works at the maximum power to
make the room cool rapidly.
During operation, press the Full power button.
TO CANCEL
Press the Full power button again.
The Full power operation will also be cancelled when the operation
mode is changed, or when the unit is turned off.
NOTE:
•
The air conditioner will operation at “Extra HIGH” fan speed for 5
minutes, and then shift to “HIGH” fan speed.
•
You can not set the temperature or fan speed during the Full power
operation.
•
To turn off the Full power lamp, press the DISPLAY button.
1.16. Self Clean operation
Heating or Fan operation and Cluster operation are performed simulta-
neously.
The judgment of whether Heating or Fan operation is used is based on
the outside air temperature at 3 minutes after the start of internal
cleaning.
The operation stops after 40 minutes.
•
During this operation the horizontal louver moves and stays two posi-
tions.
It turns to the lower direction and stays for 30 minutes.
Next moves upward and stays for 10 minutes.
1.17. Plasmacluster Ion function
The Plasmacluster Ion generator inside the air conditioner will release
positive and negative plasmacluster ions into the room.
ApproXimately the same numbers of positive and negative ions
released into the air will reduce some airborne mold.
If the Plasmacluster Ion generation function is operated together with
the air conditioner operation, the indoor unit fan speed and louver
direction are in accordance with the air conditioner settings.
If the Plasmacluster Ion generation function is used without operating
the air conditioning function, the indoor unit fan operates at a very low
speed and the upper louver is angled upward and the lower louver
remains horizontal. (The airflow volume and direction can be changed
by using the remote control.)
1.18. Power ON start
If a jumper cable is inserted in the location marked with HAJP on the
indoor unit control printed circuit board (control PCB), connecting the
power cord to an AC outlet starts the air conditioner in either cooling or
heating mode, which is determined automatically by the room temper-
ature sensor.
When a circuit breaker is used to control the ON/OFF operation,
please insert a jumper as described above.
1.19. ON timer
The ON timer can be activated by pressing the ON timer button. When
the ON timer is activated, the operation start time is adjusted based on
fuzzy logic calculations 1 hour before the set time so that the room
temperature reaches the set temperature at the set time.
1.20. OFF timer
The OFF timer can be activated by pressing the OFF timer button.
When the OFF timer is set, the operation stops after the set time.
When this timer is set, the compressor operating frequency lowers for
quieter operation, and the room temperature is gradually varied after
one hour (reduced 1
°
C three times (max. 3
°
C) in heating, or increased
0.3
°
C three times (max. 1
°
C) in cooling or dehumidifying operation) so
that the room temperature remains suitable for comfortable sleeping.
1.21. Auto restart
When power failure occurs, after power is recovered, the unit will auto-
matically restart in the same setting which were active before the
power failure.
1.21.1 Setting not memorized
• Timer setting
• Full power operation setting
• Self clean operation
27ºC
+0
+0.5
-1.0
-1.5
25ºC
25ºC
28ºC
22ºC
22ºC
Room Temperature
Preset
temperature
-
The remote control will display”
“
The temperature display will go off.
The green Full power lamp (
) on the unit will light up.
٨
٨
٨
The green Full power lamp (
) on the unit will turn off.
٨
Heating operation
Fan operation
24
O
C
Outside air temperature
Heating operation
Set temperature
Activation of
OFF timer
1 hour
later
Max.
1.5 hours
later
Max.
2 hours
later
Timer setting
reached
1 hour
later
Max.
1.5 hours
later
Max.
2 hours
later
Timer setting
reached
Activation of
OFF timer
Set temperature
-1
O
C
-1
O
C
-1
O
C
0.3
O
C
0.3
O
C
0.3
O
C
Cooling/dehumidifying operation