MX-M182 SIMULATIONS 7-12
10
-
Toner motor operation
Used to check the operation of the toner motor.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or
[START] key, and the toner motor is rotated for about 30sec.
After completion of the process, the machine shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window.
14
-
Trouble cancel (except for U2)
* Used to cancel EEPROM writing troubles such as H trouble and execute the hard reset.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or
[START] key to clear the trouble other than U2.
16
-
U2 trouble cancel
*
Used to cancel the U2 trouble and execute the hard reset.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or
[START] key to clear the U2 trouble.
20
01
Maintenance counter clear
Used to clear the maintenance counter.
Press [OK] key or [START] key on the following window, the maintenance counter is cleared and the
machine returns to the sub code input window.
21
01
Maintenance cycle setting
Used to set the maintenance cycle. When this simulation is executed, the current set value is displayed.
Enter a desired code with numeric keys and press [START] key. The set value is saved in the EEPROM and
the machine returns to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
Default:
4
Main
code
Sub
code
Contents
Remark
Sim10 TONER MOTOR
PRESS OK KEY EXEC
Sim10 TONER MOTOR
EXEC
[OK] key or [START] Key
(Execution start window)
(Execution window)
Sim14 TROUBLE CLEAR
AER YOU SURE? EXEC
TROUBLE CLEAR
(WITHOUT U2)
(Execution start window)
Sim16 TROUBLE CLEAR
AER YOU SURE? EXEC
U2 TROUBLE CLEAR
(Execution start window)
Sim20-1 COUNTER CLR
AER YOU SURE? EXEC
MAINTENANCE COUNTER
CLEAR
Sim21-1 CYCLE SET.
4
4
[ 0- 5]
1:MAINTE CYCLE
0: 5K (5,000 sheets)
1: 7.5K (7,500 sheets)
2: 10K (10,000 sheets)
3: 25K (25,000 sheets)
4: 50K (50,000 sheets)
5: FREE (999,999 sheets)
(Setting range: 0 - 5)