MX-M182 SIMULATIONS 7-29
43
02
Fusing temperature setting 2
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the current display value is increased. For the set value, refer to Table 1.
Every time when [ ] key is pressed, the current display value is decreased. For the set value, refer to Table 1.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Window display
Setting item
Setting range
1: SUSPEND
Sub thermistor temperature when shifting to high temperature alarm
150 - 230 *1
2: RESUME
Sub thermistor temperature when canceling high temperature alarm
150 - 230 *2
3: COOLDOWN
Main motor rotation time (sec) after completion of a JOB
0 - 90
*1, *2: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
Table 1:
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
Default:
SUSPEND: 230
RESUME: 180
COOLDOWN: 0
03
Fusing temperature setting 3
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the current display value is increased. For the set value, refer to Table 1
and 2.
Every time when [ ] key is pressed, the current display value is decreased. For the set value, refer to
Table 1 and 2.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Window display
Setting item
Setting range
1: PREHEAT
Main thermistor target temperature during preliminary heating
80 - 160 *1
2: WARMUP1
When the initial temperature is below 120°C during warm-up
150 - 230 *2
Main thermistor target temperature
3: WARMUP2
When the initial temperature is above 120°C during warm-up
150 - 230 *3
Main thermistor target temperature
*1: When the set value is increased by 1, the target temperature is increased by 10°C. (Refer to Table 2.)
*2: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
*3: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
Table 1:
Table 2:
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
Default:
PREHEAT: 110
WARMUP1: 160
WARMUP2: 150
Main
code
Sub
code
Contents
Remark
Sim43-2 FUSER TMP 2
1:SUSPEND
2:RESUME
3:COOLDOWN
230
180
0
230
NO.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Temperature (°C) 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230
Sim43-3 FUSER TMP 3
1:PREHEAT
2:WARMUP1
3:WARMUP2
110
100
150
110
NO.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Temperature (°C) 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230
NO.
0
1
2
3
4
5
6
7
8
Temperature (°C) 80
90 100 110 120 130 140 150 160