MX3500N SIMULATION 7 – 118
<Adjustment item and content>
When one of 1-4 in the above table is selected, the guide plate is
shifted to each position of the four widths of the guide plate shown
in the table below. The value of the document width sensor
(RSPF_WIDTH) A/D value is saved to EEPROM.
<Guide plate positions and widths on the mechanism and A/D
values to be saved>
53-7
Purpose
Adjustment
Function (Purpose)
Used to enter the adjustment value of the
main unit RSPF/DSPF document tray size
adjustment value. SIM53-06 A/D value
manual input.
Section
RSPF/DSPF
Item
Operation
Operation/Procedure
1) Select the set item with [
↑
] and [
↓
] buttons.
The highlighted section of the set value is switched and dis-
played on the set setting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
2) Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3) When [OK], [
↑
], [
↓
] button, [COLOR], or [BLACK] key is
pressed, the currently entered value is set.
<Display item, set range, and default values>
* A/D is 10 bit.
53-8
Purpose
Adjustment
Function (Purpose)
Used to adjust the RSPF/DSPF scan posi-
tion.
Section
RSPF/DSPF
Item
Adjustment
Operation/Procedure
1)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
2)
When [OK] button is pressed, the currently entered value is
set.
<Display item, set range and default value>
• When the set value is increased by 1, the distance between the
home position and the RSPF/DSPF scan position is increased by
0.1mm.
• When the set value is changed by 1, the position is shifted by
0.1mm.
* Since the distance of RRCA-S and RSPF/DSPF scan position is
changed, RRCA are not changed by this adjustment value.
No.
Display
Content
1
TRAYVOLMAX
Tray size volume maximum value
2
TRAYVOLA4R
Tray volume A4R size adjustment value
3
TRAYVOLA5R
Tray volume A5R size adjustment
4
TRAYVOLMIN
Tray size volume minimum value
No.
Guide plate
position
Widths on the mechanism
A/D value,
code in
the figure
below
Remark
AB
series
INCHI
series
Code in the
figure below
1
Maximum
position
303.3
303.3
WIDTH_MAX
AD_MAX
2
Middle
position (L)
210
215,9
WITH_P1
AD_P1
A4R OR
LTR
3
Middle
position
(S)
148.5
139.7
WITH_P2
AD_P2
A5R OR
INVR
4
Minimum
position
118
118
WITH_MIN
AD_MIN
0
SIMULATION
NO.53
̆
06
TEST
SPF
TRAY
ADJUSTMENT
CLOSE
EXECUTE
TRAYVOLMAX
TRAY
ADJUSTMENT.
PRESS
[EXECUTE]
TO
START
Item
Display
item
Guide plate position
Set range
Default
value
A
AD_MAX
Maximum position
0 to 1023
RSPF: 948
DSPF: 66
B
AD_P1
Middle position (L)
0 to 1023
RSPF: 517
DSPF: 438
C
AD_P2
Middle position (S)
0 to 1023
RSPF: 219
DSPF: 699
D
AD_MIN
Minimum position
0 to 1023
RSPF: 68
DSPF: 893
Item
Display item
Description
Set
range
Default
value
A
ADJUST VALUE
RSPF/DSPF scan
position adjustment
1 to 99
50
CLOSE
0
A:
A
㧦
791
B
㧦
713
C
㧦
456
D
㧦
66
;
AD_MAX
;
AD_P1
;
AD_P2
;
AD_MIN
SIMULATION NO.53-07
SPF TRAY ADJUSTMENT(MANUAL).
791
[
0~ 1023
]
OK
TEST
0
A:
A
㧦
50
ADJUST
VALUE
SIMULATION NO.53-08
SPF SCANNING POSITION ADJUSTMENT
50
[
1
~
99 ]
OK
TEST
CLOSE
Содержание MX 3501N - Color Laser - Copier
Страница 64: ...MX3500N ADJUSTMENTS 6 19 E F Yellow C D Magenta A B Cyan ...
Страница 390: ...MX3500N PHOTOCONDUCTOR SECTION i 7 3 6 7 9 8 10 2 5 7 9 1 4 11 ...
Страница 444: ...Memo ...
Страница 445: ...Memo ...