MX3500N SIMULATION 7 – 106
<Error displays and contents in error end>
Error
code
Error display
Error content
Detail of content
Compulsory
end error
-
SUSPENDED
Door open end
Door open during operation
-
SUSPENDED
CA end
Pressing [CA] button during operation
-
-
OFF end
Unconfirmed operation (power OFF) during operation
Basic error
1
TONER EMPTY
Toner empty
BK or all colors toner empty detection
2
TONER BEFORE
BEHAVIOR
Other conditions
Other conditions
4
SENSOR CALIBRATION
Calibration error
With 3 times of retry of F or R, the target is not reached.
5
TIME OVER
Time error
Data is not acquired for 90sec from data acquisition
7
PROCESS CONTROL
Process control error
Process control error detection
Sub scan
adjustment
error
10
MAIN BLACK FRONT
Number error sub scan BLACK F
The number of pitch data is not the specified number.
11
MAIN BLACK FRONT
Pitch error sub scan BLACK F
The pitch data is not in the specified allowable range.
15
SUB BLACK REAR
Number error sub scan BLACK R
The number of pitch data is not in the specified range.
16
SUB BLACK REAR
Pitch error sub scan BLACK R
The pitch data is not in the specified allowable range.
20
SUB CYAN FRONT
Number error sub scan CYAN F
The number of pitch data is not the specified number.
21
SUB CYAN FRONT
Pitch error sub scan CYAN F
The pitch data is not in the specified allowable range.
22
SUB CYAN FRONT
Adjustment value error sub scan
CYAN F
The calculation result value is not in the specified allowable
range.
23
SUB CYAN FRONT
Result value error sub scan CYAN F
The variation of the calculation result value is over the
specified allowable range.
25
SUB CYAN REAR
Number error sub scan CYAN R
The number of pitch data is not the specified number.
26
SUB CYAN REAR
Pitch error sub scan CYAN R
The pitch data is not in the specified allowable range.
27
SUB CYAN REAR
Adjustment value error sub scan
CYAN R
The calculation result value is not in the specified allowable
range.
28
SUB CYAN REAR
Result value error sub scan CYAN
R
The variation of the calculation result value is over the
specified allowable range.
30
SUB MAGENTA FRONT
Number error sub scan MAGENTA
F
The number of pitch data is not the specified number.
31
SUB MAGENTA FRONT
Pitch error sub scan MAGENTA F
The pitch data is not in the specified allowable range.
32
SUB MAGENTA FRONT
Adjustment value error sub scan
MAGENTA F
The calculation result value is not in the specified allowable
range.
33
SUB MAGENTA FRONT
Result value error sub scan
MAGENTA F
The variation of the calculation result value is over the
specified allowable range.
35
SUB MAGENTA REAR
Number error sub scan MAGENTA
R
The number of pitch data is not the specified number.
36
SUB MAGENTA REAR
Pitch error sub scan MAGENTA R
The pitch data is not in the specified allowable range.
37
SUB MAGENTA REAR
Adjustment value error sub scan
MAGENTA R
The calculation result value is not in the specified allowable
range.
38
SUB MAGENTA REAR
Result value error sub scan
MAGENTA R
The variation of the calculation result value is over the
specified allowable range.
40
SUB YELLOW FRONT
Number error sub scan YELLOW F
The number of pitch data is not the specified number.
41
SUB YELLOW FRONT
Pitch error sub scan YELLOW F
The pitch data is not in the specified allowable range.
42
SUB YELLOW FRONT
Adjustment value error sub scan
YELLOW F
The calculation result value is not in the specified allowable
range.
43
SUB YELLOW FRONT
Result value error sub scan
YELLOW F
The variation of the calculation result value is over the
specified allowable range.
45
SUB YELLOW REAR
Number error sub scan YELLOW R
The number of pitch data is not the specified number.
46
SUB YELLOW REAR
Pitch error sub scan YELLOW R
The pitch data is not in the specified allowable range.
47
SUB YELLOW REAR
Adjustment value error sub scan
YELLOW R
The calculation result value is not in the specified allowable
range.
48
SUB YELLOW REAR
Result value error sub scan
YELLOW R
The variation of the calculation result value is over the
specified allowable range.