12) Plasmacluster unit drive circuit
The plasmacluster unit is the power supply unit that supplies the high voltage to generate ion from the cluster
electrode, and it can be activated by inputting AC220-240V into it.
When the solid state relay SSR1 is turned on, the voltage for commercial power supply drops in the resistor R124
and approximately AC90-110V is applied to the plasmacluster unit.
During operation, it outputs " H " / " L " from the pin 39 of the microcomputer LSI-1, turns on and off Q121, and
controls and drives SSR1.
13) EEPROM circuit
During operation, data integrated with the operation time of the fan motor (dirtiness of the filter) is read and written
into EEPROM (IC-1) using the repetitive signals of " H " and " L " that are input and output from the pins 6 and 7
of the microcomputer LSI-1.
5. TEST MODE
(1) Outline
Test mode is the mode for testing operation of circuit PWB, or sensors and the load output.
(2) Setting method
When turning on the power while pressing the [OFF TIMER button] of the main body, the buzzer sounds "peep"
and enters the "test mode".
(3) Canceling method
In all test modes, when pressing the [POWER ON/OFF button] on the remote controller, the buzzer sounds
"peep" and the "test mode" is canceled and becomes the initial state at normal halt.
(4) Contents
By operating and checking, the check of circuit PWB, sensors, and the load output of operation can be performed
as follows.
PWB ASSEMBLY
Load Output
LED
No.
Operation
Operation mode
OFF timer
Cluster
Buzzer
Point to be check
Fan
Cluster
Odour
Auto
Max
Silent
4 hours
1 hour
ion
Silent
Max
Drive
Sensor
Green
Green
Green
Green
Green
Blue
PORT No.
25
39
41
2
3
4
5
6
1
–
LED No.
1
Turn the power on while holding down
Model select, memory ON/OFF check
the "OFF TIMER" button on the main unit.
2
Press the "POWER ON/OFF" button
EEPROM version No. [upper side] check
on the main unit.
3
Press the "FAN CONTROL" button
EEPROM version No. [lower side] check
on the main unit.
(High)
4
Press the "OFF TIMER" button
(High)
5
Press the "Auto" button
(High)
6
Press the "Manual" button
Fan motor rotation speed [upper side] check
Check the rotation speed [upper side] of
on the remote controller.
the fan motor (Max).
8
Blow gas to the Odour sensor.
9
Power OFF
2) Error display list
No.
Concerned item No.
Error display, symptom
Error contents
Probable cause
Reference
1
item 2
Auto lamp flickers, operation impossible
EEPROM communication error
EEPROM circuit failure, EEPROM failure
2
item 2
Auto lamp lights on, operation impossible EEPROM data error
Wrong EEPROM data
3
All items
Silent lamp flickers.
Fan motor rotation speed error
Fan motor circuit failure
Check the version No. of EEPROM.
(Version No. 29 = 00011101)
: ON
: Peep sound, : Pip sound
on the main unit.
on the remote controller.
(High)
7
Press the "OFF Timer" button
Fan motor rotation speed [lower side] check
on the remote controller.
1) Check the voltage : VDD = 5V±0.3V
Check the rotation speed [lower side] of
the fan motor (Max).
OK if in the range of ±1 in binary digit.
The "Cluster ion" lamp lights on after
10 seconds has passed from the start of
item 2.
The "Auto" lamp lights on.
Содержание FU-28H-S