FO-DC635U
2 – 38
SW76 No. 7 MTF correction in half-tone mode
In the half tone mode, image area is separated from character area
and processed separately to eliminate unclear character transmission.
This switch is used to change the criteria of judgment of separation.
When "Strong" (= 1) is selected, more area is judged as character
area, providing clearer characters.
On the contrary, however, edges of image area may be emphasized. It
is advisable to restrict the use of this function only when clear charac-
ters must be transmitted, and to use the function of "Weak" (= 0) for
general cases.
SW76 No. 8 MTF intensity in half-tone mode
This allows selection of MTF correction (dimness correction) in the half
tone mode. When "NO" (= 1) is selected, the whole image becomes
soft and mild, On the contrary, however, mildness of characters will be
reduced. Normally set to "NO" (= 1).
SW77 No. 1 Cassette define LTR / A4: Tray
A4 cassette can be used.
Set "0" or "1" for all of three bits.
Do not change the setting during printing.
SW77 No. 2 Cassette define LTR / A4: 1st
A4 cassette can be used.
Set "0" or "1" for all of three bits.
Do not change the setting during printing.
SW77 No. 3 Cassette define LTR / A4: 2nd
A4 cassette can be used.
Set "0" or "1" for all of three bits.
Do not change the setting during printing.
SW77 No. 4 ~ No.7 Reserved
Set to "1".
SW77 No. 8 Reserved
Set to "0".
SW78 No. 1 Reserved
Set to "1".
SW78 No. 2, No. 3 Reserved
Set to "0".
SW78 No. 4 Metric based resolution
Select mm (metric) or inch to convert the resolution of received data.
SW78 No. 5 ~ No.7 Reserved
Set to "0".
SW79 No. 1 Secure billing code
When the tel. billing code function is ON, the operation of secure billing
code is enabled.
SW79 No. 2 Pause with SHIFT key
The SHIFT key pause time is set.
SW79 No. 3 Reserved
Set to "0".
SW79 No. 4 ~ No. 8 Z key pause time (250ms unit)
The Z key pause time is set.
SW80 No. 1 Separate feature
The separate mode ON/OFF is set.
SW80 No. 2 ~ No. 4 Reserved
Set to "0".
SW80 No. 5 Addition of header (Sender information)
ON/OFF of addition of header (sender information) to various list is
set.
SW80 No. 6 DTMF sending by the panel test
When ten keys are pressed in the Panel Test Mode of the diagnosis,
the corresponding DTMF signals are output.
SW80 No. 7 Power save mode
To switch power save mode system either to real time or to timer.
SW80 No. 8 Ring control for line-2
The ringer ringing ON/OFF is set when incoming call is received
through the line-2.
SW81 No. 1 Reserved
Set to "1".
SW81 No. 2 Reserved
Set to "0".
SW81 No. 3 ~ No. 8 Reserved
Set to "1".
SW82 No. 1 Reserved
Set to "0".
SW82 No. 2 Reserved
Set to "1".
SW82 No. 3 Reserved
Set to "0".
SW82 No. 4 Reserved
Set to "1".
SW82 No. 5 ~ No. 8 Reserved
Set to "0".
SW83 No. 1 ~ No. 5 Reserved
Set to "0".
SW83 No. 6 Reserved
Set to "1".
SW83 No. 7 Reserved
Set to "0".
SW83 No. 8 Reserved
Set to "1".
SW84 No. 1 ~ No. 4 Reserved
Set to "0".
SW84 No. 5 ~ No. 8 Reserved
Set to "1".
SW85 No. 1 ~ No. 4 Reserved
Set to "0".
SW85 No. 5 ~ No. 8 Waiting time of duplex scan
When the duplex scan is enabled, set the waiting time until the
reversed document is reloaded after the ADF reads document.
SW86 No. 1, No. 2 Reserved
Set to "0".
SW86 No. 3 Network scan (Files are split when transferring TIFF/
PDF files)
Determine whether to split TIFF or PDF files or not before transfer.
Содержание FO-DC635U
Страница 3: ... ii MEMO FO DC635U ...
Страница 87: ...FO DC635U 5 21 MEMO ...
Страница 103: ...FO DC635U 6 16 16 Control PWB parts layout Top side F1 F2 F5 The CONTROL PWB of the model employs lead free solder ...
Страница 106: ...FO DC635U 6 19 2 LIU PWB parts layout Top side The LIU PWB of the model employs lead free solder ...
Страница 107: ...FO DC635U 6 20 3 LIU PWB parts layout Bottom side The LIU PWB of the model employs lead free solder ...
Страница 110: ...FO DC635U 6 23 3 Printer PWB parts layout Top side ...
Страница 111: ...FO DC635U 6 24 4 Printer PWB parts layout Bottom side ...
Страница 124: ...FO DC635U 8 2 MEMO ...
Страница 165: ...FO DC635U 41 ...