SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW49
1
Time
designation 2
(hour) print on
the activity
report
Used to set time designation 2 (hour) to be printed on
the activity report.
00
0
139
When set to 24
– 31, it is set
to “00”.
2
0
3
0
4
0
5
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW50
1
Time
designation 2
(min) print on
the activity
report
Used to set time designation 2 (min) to be printed on the
activity report.
00
0
139
When set to 59
– 63, it is set
to “00”.
2
0
3
0
4
0
5
0
6
0
7
Reserved
0
8
Reserved
0
SW51
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
CED detection
time
Used to set CED/ANSam signal detection time. When
the CED/ANSam signal is detected for duration of the set
time, it is recognized.
1000 ms
0
7
Reserved
0
8
Reserved
0
SW52
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
RTN reception
error process
Used to set whether RTN reception is treated as a
communication error or not.
Treated
as an
error
0
6
V.34 mode
function in
manual
communication
Used to set ON/OFF of V.34 mode function on the other
party side in manual communication. If SW52-7 is set to
“0: OFF”, though SW52-6 is set to “1: ON”, V.34 mode is
disabled.
ON
1
7
V.34 mode
function
Used to set ON/OFF of V.34 mode function on the
machine.
ON
1
8
V.34 control
channel
communication
speed
Used to set V.34 mode communication speed of the
control channel. If the other party is not set to 2400 bps
Enable, it is set to 1200 bps.
1200 bps
0
SW47 Bit No.
1 2 3 4 5
Set range
00 – 23
Input of 2 digits (Binary input)
SW48 Bit No.
1 2 3 4 5 6
Set range
00 – 59
Input of 2 digits (Binary input)
1: 500 ms
0: 1000 ms
1: Not treated as an error
0: Treated as an error
1: ON
0: OFF
1: ON
0: OFF
1: 2400 bps
0: 1200 bps
DM-FX1
6 – 18