SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW41
1
Number of
recall times in
case of busy
state
Used to set the number of recall times in case of busy
state of the other party or when call does not reach the
other party.
2 times
0
112
When it is set
to 15 or more
times, set to 2.
2
0
3
0
4
0
5
0
6
0
7
1
8
0
SW42
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Auto select
between
Manual/Auto
reception
Used to set Enable/Disable of auto select between
Manual/Auto reception
Disable
0
5
Call number of
auto select
between
Manual/Auto
reception
Used to set the call number of auto select between
Manual/Auto reception.
9 times
1
When “0000” is
set, the initial
value of “1001”
is set.
When set to 10
or more times,
set to 9.
6
0
7
0
8
1
SW43
1
DTMF signal
send time
Used to set the DTMF signal send time when sending it.
The set range is 60 – 310 ms by binary input of “10(ms)
×
N”. “N” can be set in the range of 6 – 31.
110 ms
0
When set to
under “00101”,
set to “01011”.
2
1
3
0
4
1
5
1
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW44
1
Tone/Pulse
default setup
Used to set the employing line (dial setup). Selection is
available in 10PPS and TONE.
TONE
1
102
When set to
“
∗
1”, set to “10”
2
1
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
1
7
Reserved
0
8
Reserved
0
SW41 Bit No.
1 2 3 4 5 6 7 8
Set range
0 – 14 times (Binary input)
0: Recall inhibited
1: Enable
0: Disable
SW42 Bit No
5 6 7 8
Set range
1 – 9 times
SW43 Bit No.
1 2 3 4 5
Set range
60 – 310 ms
When set to outside of the range:
110 ms in the increment of 10 ms
(Binary input)
SW44 Bit No.
1 2
10 PPS
0 0
TONE
1 0
DM-FX1
6 – 16