Main code
Sub code
Content
26
02
SPF setup
When this simulation is executed, the currently set SPF code number is displayed. Enter the code number of the
SPF to be set and press the PRINT switch. The setup is changed.
03
Second cassette setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of the second cassette is displayed.
2. Enter the code number and press the start key. The setting is changed.
04
Machine duplex setup
(Operation/procedure)
1. When this simulation is executed, the currently set duplex code number is displayed.
2. Enter the code number corresponding to the duplex and press the ENTER key, and the setup will be changed.
06
Destination setup
(Operation/Procedure)
1. When this simulation is executed, the currently set destination code number is displayed.
2. Enter the code number corresponding to the destination and press the START key, and the setting will be
changed.
07
Machine conditions check
(Operation/Procedure)
When this simulation is executed, the current machine setting is displayed.
20
Rear edge void setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of rear edge void setting is displayed.
2. Enter the code number of rear edge void setting and press the START key, and the setting will be changed.
30
CE mark conformity control ON/OFF setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of CE mark application is displayed.
2. Enter the code number of CE mark application and press the START key, and the setting will be changed.
Code No.
SPF
0
Without SPF
1
With SPF (Setup is required when installing FAX.)
2
With RSPF
Code number
Second cassette
0
Without second cassette
1
With second cassette
Code number
Duplex
0
Without Duplex
1
With Duplex
Code number
Destination
0
Inch series
1
EX AB series
2
Japan AB series
CPM
Copy quantity display
10 cpm
10
12 cpm
12
15 cpm
15
The machine type is shown with the lamp display.
AL series: None
AR-A series: AE mode lamp ON
AR-B series: TEXT mode lamp ON
DM series: Photo mode lamp ON
Code number
Rear edge void setting
0
Rear edge void allowed
1
Rear edge void not allowed
Code number
CE mark application setting
0
CE mark application control OFF
1
CE mark application control ON
DM-1505
9 – 5
Содержание DM-1500
Страница 125: ...OPU DM 1505 12 9 ...