Main code
Sub code
Content
22
06
DV counter display
The display method is the same as the total count value display.
08
SPF counter display
The display method is the same as the total count value display.
12
Drum counter display
The display method is the same as the total count value display.
14
P-ROM versiondisplay
The P-ROM version is displayed in 3 digits on the value display section.
(AR, DM, PCL models: 100% Zoom lamp display)
17
Copy counter display
The display method is the same as the total count value display.
18
Printer counter display
The display method is the same as the total count value display.
21
Scanner counter display
The display method is the same as the total count value display.
22
SPF jam total counter display
The display method is the same as the total count value display.
24
01
Jam total counter clear
When the PRINT switch is pressed, the jam total count value is reset to 0.
04
SPF counter clear
When the PRINT switch is pressed, the SPF count value is reset to 0.
07
Drum counter clear
When the PRINT switch is pressed, the drum count value is reset to 0.
08
Copy counter clear
When the PRINT switch is pressed, the copy count value is reset to 0.
09
Printer counter clear
When the PRINT switch is pressed, the printer count value is reset to 0.
13
Scanner counter clear
When the PRINT switch is pressed, the scanner count value is reset to 0.
14
SPF jam total counter clear
When the PRINT switch is pressed, the SPF jam total count value is reset to 0.
25
01
Main motor system ON + Cooling fan low speed (For the duplex model, the duplex motor is simultaneously
turned on.)
(Operation/Procedure)
When the START key is pressed, the main motor is rotated for 30 sec.
To save toner consumption, the different operations are executed depending on installation of the developing unit.
⋅
When the developing unit is installed, the developing bias, the main charger, and the grid are also outputted.
⋅
When the developing unit is not installed, only the motor is rotated.
∗
Do not turn on the door open/close switch forcibly to execute this simulation.
10
Polygon motor ON
(Operation/Procedure)
When the START key is pressed, the polygon motor is operated for 30sec.
26
01
Manual feed setup
(Operation/Procedure)
1. When this simulation is executed, the currently set bypass code number is displayed.
2. Enter the code number corresponding to the bypass and press the START key, and the setting will be
changed.
Code number
Bypass
0
Single bypass
1
Multi bypass
DM-1505