E-25
ENGLISH
Electric wiring
• Be sure to disconnect all supply circuits in case of wiring work.
• All field supplied parts and materials must conform to local laws and regulations.
• For electric wiring, refer to WIRING DIAGRAM attached to the unit body.
Wiring of the indoor unit.
Remove the control box lid, pull the wires inside through rubber bush A and wiring according to
the WIRING DIAGRAM , then tighten it with clamp.
Wiring of the controller
. Remove the control box lid, pull wires inside through rubber bush B and connect to the
controller.
2. Wrap the wire with sealing pad.
3. After wiring, tighten it with clamp and fix the control box lid.
4. Connect the rubber wire (3-cords) to the power supply terminal board in properly.
Precautions:
Be sure to connect the indoor unit and outdoor unit at right poles.
Drain hose
Test hole cover
Test hole
Drain vent for repair use (plastic
stopper is included) (drain the water
in waterspout by this outlet vent)
Pouring water into the
outlet vent terminal
Plastic water pot (The length of the
pipe should be about 00mm.)
Pouring water into the test hole
Above 00mm
P
ow
er
: 2
20
-2
40
V
~5
0H
z
power supply terminal board
Clamp
Rubber bush A
Rubber bush B
Control box lid (2)
Seal here to avoid leakage
Clamp
Control box lid (2)
GX-X8JR
GX-X24JR/GX-X36JR
Terminal board
GREE_cassette_eng.indd 25
08.10.28 11:42:46 AM