E-9
ENGLISH
Memory function setting
When the unit is shut off, press the MODE button for 0
seconds to switch set values so as to decide if the unit
operating status or shut off status is memorized after a
power fail.
If the set temperature area displays "0", it means the
unit operating status or shut off status shall be memorized
after a power fail; "02" means the operating status or shut
off status will not be memorized.
Press the ON/OFF button to store the set value and exit
the setting.
Even if the ON/OFF button is not pressed, the system
will store the set value and exit the setting after 0
seconds, and return to the normal unit off display.
Failure display
When there is failure in the unit operation, the “ERROR”
will flash on the display of the wire controller and the
error code will also be displayed. When there are multiple
failures, the error codes will be displayed one after one
on the wire controller. The two digits indicate the detailed
the error code.
The Error Codes Definitions are as Follows:
Error code
Fault
E0
Water pump malffunction
E
High pressure protection of compressor
E2
Indoor anti-frozen of compressor
E3
Low pressure protection of compressor
E4
Air discharge high-temperature protection of compressor
E5
Overload protection of compressor
E6
Transmit malfunction
E8
Indoor fan protection
E9
Water flow protection
F0
Malfunction of indoor environment sensor at air return vent
F
Evaporator sensor malfunction
F2
Condenser sensor malfunction
F3
Outdoor environment sensor malfunction
F4
Malfunction of air discharge sensor
F5
Malfunction of environment sensor on displayer
FF
Connected control communications Failure
EE
Buttons are locked (not failure)
GREE_cassette_eng.indd 9
08.10.28 11:42:42 AM