AR-5618S SIMULATIONS 7-5
07
01
Warm-up display and aging with
jam
Copying is repeated to make the set copy quantity. When this simulation is executed, warm-up is
started and warm-up time is counted up every second from 0 and displayed. After completion of
warm-up, warm-up time count is stopped. When the [CA] key is pressed, the START indicator lights
up. After that, when the copy quantity is inputted with keys and the [START] key is pressed, copying
is repeated to make the set copy quantity. (Intermittent 0 sec)This simulation is canceled by turning
off the power or performing a simulation that executes hardware reset.
06
Intermittent aging
Copying is repeated to make the set copy quantity. When this simulation is performed, warm-up is
performed and the START indicator is lighted. Enter the copy quantity with the key and press the
[START] key, and copying is repeated to make the set copy quantity, the ready state remains for 3
sec, and copying is repeated again to make the set copy quantity. These operations are repeated.
This simulation is canceled by turning off the power or performing a simulation that executes
hardware reset.
08
Shifting with warm-up display
(Shifting similar to pressing the CA
key)
When the simulation code is entered, warm-up is started and warm-up time is counted up every
second from 0 and displayed. When the [CA] key is pressed during counting up, the display section
displays "0" and count-up process stops. However, warm-up is continued.
After completion of warm-up, counting is stopped. Press the [CA] key to terminate the simulation
mode. (This simulation is similar to SIM07-01, but without the aging function.)
08
01
Developing bias output
When the [START] key is pressed, the developing bias signal is turned ON for 30 sec.
However, to calculate the actual output value is calculated, execute SIM25-01.
After completion of the process, the machine goes into the sub code input standby mode.
02
Main charger output (Grid = HIGH) When the [START] key is pressed, the main charger output is supplied for 30 sec in the grid voltage
HIGH mode. After completion of the process, the machine goes into the sub code input standby
mode.
03
Main charger output (Grid = LOW) When the [START] key is pressed, the main charger output is supplied for 30 sec in the grid voltage
LOW mode. After completion of the process, the machine goes into the sub code input standby
mode.
06
Transfer charger output
Select an output mode with the [AUTO/TEXT/PHOTO] key and press the [START] key. The transfer
charger output is delivered for 30 sec in the selected mode.
After 30 sec of transfer charger output, the machine goes into the sub code entry standby mode.
09
01
Duplex motor forward rotation
check
(Duplex model only)
The duplex motor is driven in forward direction (in the paper exit direction) for 30 sec.
During the process, the display section displays the sub code.
After completion of the process, the machine goes into the sub code input standby mode.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
02
Duplex motor reverse rotation
check
(Duplex model only)
The duplex motor is driven in reverse direction for 30 sec.
During the process, the display section displays the sub code.
After completion of the process, the machine goes into the sub code input standby mode.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
04
Duplex motor RPM adjustment
(Duplex model only)
When any key input is made, it is displayed on the display section.
When the [START] key is pressed, the set code data are acquired and stored in the EEPROM, and
the machine goes into the sub code input standby mode.
When, however, the [START] key is pressed outside the set range, it is not assured.
At that time, when the [Interrupt] key is pressed, the data are not rewritten and the machine goes into
the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated without rewriting the data.
05
Duplex motor switchback time
adjustment
(Duplex model only)
When any key input is made, it is displayed on the display section. When the [START] key is pressed,
the set code data are acquired and stored in the EEPROM, and the machine goes into the sub code
input standby mode.
At that time, when the [Interrupt] key is pressed, the data are not rewritten and the machine goes into
the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated without rewriting the data.
Main
code
Sub
code
Contents
Details of operation
•Small size is Letter R (A4R) or smaller.
* Duplex model only
LED
Output mode
AUTO indicator
TEXT indicator
AUTO indicator & PHOTO indicator
TEXT indicator & PHOTO indicator
AUTO & TEXT & PHOTO indicator
Normal size width: Front surface
Normal size width: Back surface*
Small size width: Front surfac
Small size width: Back surface*
Bypass tray indicator mode
Set range: 1 - 13
Default: 4
(Change quantity 1
1-2 phase 3 steps)
Set range: 50 ~ 76
Default: 50