C. Connect the desk relay harness.
a. Remove the rear coverlet of the copier.
Remove the mounting screw which holds the rear coverlet to the rear
cabinet panel, then remove the rear coverlet.
b. Connect the desk relay harness.
Remove the connector harness from the clamp which bundles the
desk relay harness together.
Next, remove the temporary connector which is attached to the con-
nector of the desk relay harness, and connect the connector from the
copier into the connector on the desk.
*
Note that the temporary connector will no longer be used.
c. Remount the rear coverlet of the copier.
Return the rear coverlet to its document position and use its mounting
screw to mount it.
D. Secure the desk on the floor.
Turn clockwise the two adjusters at the lower front of the desk to
lower them to the floor and secure the desk in place.
Use the caster lock levers on the front side (right and left) of the desk
to lock the casters in place.
Note:
Turning on the power with no desk connected causes the trouble
"U6-00," thereby disabling the machine operation.
Mounting screw
Rear coverlet
Rear cabinet panel
Clamp
connector
Rear cabinet panel
Mounting screw
coverlet
Caster
Caster lock lever
Adjuster
5 – 5