Main
Sub
Item
Content
Adjustment
code
code
range
53
02
Adjusts RADF
stopping
position (normal
paper, back
side).
0-15
SIMULATION No.53- 2
RADF STOP POSITION ADJUST VALUE SETUP
PLAIN PAPER/BOTH SIDE[XX]:_
(0~15)
INPUT SETUP VALUE AND PRESS PRINT SW
[Content] The adjustment value of the RADF document stopping position can be set. The
current setting is displayed and a new setting can be entered.
Adjustment range
RADF stopping position (normal paper back side):
0
∼
15
The stopping position increases 1 mm for every 1 marking of adjustment value.
(a)
Operation/display
[PRINT]:
If the entered value is valid, the current setting is updated and the sub code
input screen is displayed. If the entered value is not valid, the input field is
cleared and the error buzzer sounds.
If any value is not entered, no setting is made and the screen changes to
the sub code input screen.
[0-9]:
Enters new settings.
[C]:
Clears the input field.
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
05
Adjusts RADF
resist sensor.
0-127
SIMULATION No.53- 5
RADF RESIST SENSOR ADJUSTMENT
PRINT SWITCH:EXECUTE SIMULATION
• Resist sensor adjustment completed
SIMULATION No.53- 5
RESIST SENSOR ADJUSTMENT HAS COMPLETED
ADJUSTMENT VALUE:XXX
[PAUSE]KEY:END DISPLAY
[Content] The RADF resist sensor can be adjusted.
If the [PRINT] key is pressed to execute the simulation, the RADF resist sensor
reference value is adjusted and the adjusted value is displayed.
Adjustment range
RADF: 0
∼
127
(a)
Operation/display
[PRINT]:
The adjustment simulation is executed.
[PAUSE]:
The execution of the simulation is stopped and the sub code input screen is
displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
9 – 80