Main
Sub
Item
Content
Adjustment
code
code
range
50
15
Inputs
document
off-center
adjustment
value.
OFP_M: 10-90
OFP_C: 10-90
SIMULATION No.50-15
ORIGINAL OFCENTER SETTING
OC OFP_M (10~90)[XX]: XX
RADF OFP_C (10~90)[XX]: XX
[|]KEY:MOVE PRINT SW:EXECUTE
[Content] The document off-center adjustment value can be set. The current setting is
displayed and a new setting can be entered.
(a)
Operation/display
[PRINT]:
If the entered value is valid, the current setting is updated and the sub code
input screen is displayed. If the entered value is not valid, the input field is
cleared and the error buzzer sounds.
If any value is not entered, no setting is made and the screen changes to
the sub code input screen.
[0-9]:
Enters new settings.
[
→
]:
Moves the input field.
[C]:
Clears the input field.
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
51
Timing
adjustments.
SIMULATION No.51- _
1.SEPARATION NAIL TIMING SETUP
2.RESIST ROLLER ADJUSTMENTS
INPUT SUB NO. AND PRESS PRINT SWITCH
01
Inputs
separation nail
activation timing
adjustment
value.
TPSPS: 20-99
SIMULATION No.51- 1
SEPARATION NAIL TIMING
(20~90) [XX]: XX
INPUT SETUP VALUE AND PRESS PRINT SW
[Content] The drum’s separation nail activation timing adjustment value can be set. The
current setting is displayed and a new setting can be entered.
RRC
PSPS
Adjustment range
Separation nail timing
TPSPS:
20
∼
99
The timing increases 1 ms for every “+1” in adjustment value and decreases 1 ms for every
“–1”.
(a)
Operation/display
[PRINT]:
If the entered value is valid, the current setting is updated and the sub code
input screen is displayed. If the entered value is not valid, the input field is
cleared and the error buzzer sounds.
If any value is not entered, no setting is made and the screen changes to
the sub code input screen.
[0-9]:
Enters new settings.
[
→
]:
Moves the input field.
[C]:
Clears the input field.
[PAUSE]:
No setting is made and the sub code input screen is displayed.
[CA]:
The execution of the simulation is stopped and the simulation is terminated.
9 – 76