AL-2041 SIMULATION, TROUBLE CODES 10 - 6
24
05
Duplex counter clear
(AL-2041 only)
[Function]
When [START] key is pressed, the duplex counter value is cleared to 0, and "000,000" is dis-
played on the LED/display.
[Operation]
The operation is similar to simulation 22-16.
07
Drum counter clear
[Function]
When [START] key is pressed, the drum counter value is cleared to 0, and "000,000" is dis-
played on the LED/display.
[Operation]
The operation is similar to simulation 22-04.
08
Copy counter clear
[Function]
When [START] key is pressed, the copy counter value is cleared to 0, and "000,000" is dis-
played on the LED/display.
[Operation]
The operation is similar to simulation 22-04.
09
Printer counter clear
[Function]
When [OK]/[START] key is pressed, the printer counter value is cleared to 0, and "000,000" is
displayed on the LED/display.
[Operation]
The operation is similar to simulation 22-04.
13
Scanner counter clear
[Function]
When [OK]/[START] key is pressed, the scanner counter value is cleared to 0, and "000,000" is
displayed on the LCD/display.
[Operation]
The operation is similar to simulation 22-04.
14
SPF JAM total counter clear
(excluding AL-2021)
[Function]
When [START] key is pressed, the SPF JAM total counter value is cleared to 0, and "000,000" is
displayed on the LCD/display.
[Operation]
AL-2031/2041
The operation is similar to simulation 22-04.
15
Scanner mode counter clear
[Function]
When [START] key is pressed, the scanner mode counter value is cleared to 0, and "000,000" is
displayed on the LED/display.
[Operation]
The operation is similar to simulation 22-16.
25
01
Main motor operation check
(Cooling fan motor rotation
check)
[Function]
When [START] key is pressed, the main motor (and the duplex motor in the case of a duplex
model) is operated for 30sec.
To reduce toner consumption, if the developing unit is installed, the developing bias, the main
charger, and the grid are also outputted.
In this case, laser discharge is required when stopping the motor, the polygon motor is also
operated at the same time. Check for installation of the developing unit. If it is not installed, the
high voltage above is not outputted and only the motor is rotated.
To check the developing bias, install the developing unit.
After completion of 30sec operation, the machine goes into the sub code entry standby mode.
10
Polygon motor ON
[Function]
When [START] key is pressed, the Bios is called to rotate the polygon motor for 30sec.
After completion of 30sec operation, the operation is turned off with the Bios and the machine
goes into the sub code entry standby mode.
26
02
SPF setup
(excluding AL-2021)
[Function]
When this simulation is executed, the current set SPF is displayed. Enter the code number cor-
responding to the desired SPF and press [START] key to save the setting.
Main
code
Sub
code
Contents
Details of function/operation
Code number
SPF
0
SPF NO
1
SPF YES