AL-2041 SIMULATION, TROUBLE CODES 10 - 4
7
08
Shift to copy with the
warm-up display
[Function]
Enter the simulation code, and warm-up is started and warm-up time is counted for every sec-
ond from 0 and displayed.
When [Clear] key is pressed during counting up, "0" is displayed on the display and counting is
stopped. However, warm-up is continued.
After completion of warm-up, counting is terminated. (The aging function is removed from simu-
lation 7-01.)
8
01
Developing bias
[Function]
When [START] key is pressed, the developing bias signal is turned ON for 30sec.
When, however, an actual output value is measured, use simulation 25-01.
After completion of this process, the machine goes into the sub code entry standby mode.
02
Main charger (Grid high)
[Function]
When [START] key is pressed, the main charger is outputted for 30sec in the grid voltage HIGH
move.
After completion of this process, the machine goes into the sub code entry standby mode.
03
Grid voltage (Low)
[Function]
When [START] key is pressed, the main charger is outputted for 30sec in the grid voltage LOW
move.
After completion of this process, the machine goes into the sub code entry standby mode.
06
Transfer charger
[Function]
When [START] key is pressed, the transfer charger is outputted for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
9
01
Duplex motor normal
rotation operation check
(AL-2041 only)
[Function]
Use the duplex motor Bios to drive the duplex motor in the normal direction (paper exit direc-
tion) for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
02
Duplex motor reverse
operation check
(AL-2041 only)
[Function]
Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
04
Duplex motor rotation speed
adjustment (AL-2041 only)
[Function]
When this simulation is executed, the currently set value is displayed.
Enter the adjustment value with [ ] [ ] key
and press [START] key. The entered value is stored
and the machine goes into the sub code entry standby mode. The greater the set value is, the
higher the speed is. The smaller the set value is, the lower the speed is.
(Setting range: 1 - 13, Default: 6)
10
Toner motor aging
[Function]
When [START] key is pressed, the toner motor is rotated for 30sec.
After completion of this process, the machine goes into the main code entry standby mode.
14
Cancel of troubles other than
U2
[Function]
Used to cancel troubles other than U2.
∗
Cancel troubles such as H trouble which writes data into EEPROM, and perform hardware
reset.
16
Cancel of U2 trouble
[Function]
Used to cancel U2 trouble.
When [START] key is pressed, check sum of the total counter in the EEPROM is rewritten and
hardware reset is made.
22
04
JAM total counter display
[Function]
The JAM total counter is displayed.
[Operation]
05
Total counter display
[Function]
The total counter value is displayed.
[Operation]
The operation is similar to simulation 22-04.
08
SPF counter display
(excluding AL-2021)
[Function]
The SPF counter is displayed.
[Operation]
AL-2031/2041
The operation is similar to simulation 22-04.
Main
code
Sub
code
Contents
Details of function/operation
The count value is displayed in 3 digits X 2 times repeatedly.
<Display example: 12345>
012
→
Blank
→
345
→
Blank
→
012
0.7s
0.3s 0.7s
1.0s
0.7s