AL-2041 SIMULATION, TROUBLE CODES 10 - 12
43
11
Postcard size paper fusing
temperature setting
[Function]
When the simulation is executed, the current set value is displayed.
Press [UP/UP] key to switch the setting. Press [START] key to write into the EEPROM.
The machine enters the sub code input standby state.
14
Fusing start temperature
setting
[Function]
When this simulation is started, the currently set code number is displayed.
Press [ ] [ ] key to switch the setting, and press [START] key to save it to the EEPROM.
The machine goes to the sub code entry standby mode.
Switching to each mode is made by [Density Select] key. The set value of the selected mode is
displayed on the 7seg display.
∗
The cassette feed and the manual feed are controlled similarly.
[Operation]
The operation is similar to simulation 43-01.
15
Postcard size paper fusing
control cycle synchronization
setting
[Function]
When this simulation is executed, the currently set code number is displayed.
When [UP/UP] key is pressed, setting is switched. When [START] key is pressed, setting is
written into the EEPROM, and the machine enters the sub code input standby state.
(Setting range: 0 - 20, Default: 0)
∗
When set to "0," the setting is canceled and the fusing temperature control and the paper
pass timing are not synchronized. The conventional control (control same as other paper) is
performed.
∗
When set to "1" - "20," postcards are passed in synchronization with the fusing temperature
control, ensuring stable fusing. However, the CPM becomes smaller.
∗
When set to "1" - "20" and when "set value x 0.5°C + control temperature," the fusing heater
lamp is controlled to be OFF.
Main
code
Sub
code
Contents
Details of function/operation
Code
Shift temperature (°C)
Remark
0
160
1
165
2
170
3
175
4
180
5
185
6
190
7
195
Default
8
200
Code
Set temperature (°C)
Remark
0
160
1
165
2
170
3
175
4
180
5
185
6
190
7
195
Default
8
200
9
205
10
210
Mode
LED
Default value
AL North
America
AL Europe
Maine cassette paper feed &
2nd cassette paper feed
AE mode lamp
7
7
Manual paper feed
TEXT mode lamp
7
7
Code
Synchronization
setting
Fusing heater lamp OFF
timing temperature
Remark
0
Cancel
-
Default
1
Setting
+ 0.5°C
n
n
n
n
n
n
6
+ 3.0°C
n
n
n
n
n
n
20
+ 10.0°C