AL-2020/2035/2040/2050/2060 SIMULATION, TROUBLE CODES 10 - 40
5. Trouble codes
A. Trouble codes list
B. Details of trouble codes
Main
code
Sub
code
Details of trouble
E1
00
IMC communication trouble
10
IMC trouble
13
IMC flash ROM error
81
IMC communication interface error (Parity)
82
IMC communication interface error (Overrun)
84
IMC communication interface error (Framing)
E7
01
Duplex model memory setup error, memory not-
detected error
02
LSU trouble
10
Shading trouble (Black correction)
11
Shading trouble (White correction)
16
Abnormal laser output
F5
02
Copy lamp lighting abnormality
F6
10
FAX board trouble (AL-2060 only)
H2
00
Thermistor open
H3
00
Heat roller high temperature detection
H4
00
Heat roller low temperature detection
L1
00
Feeding is not completed within the specified time
after starting feeding. (The scan head locking switch
is locked)
L3
00
Scanner return trouble
L4
01
Main motor lock detection
32
Exhaust fan motor lock detection trouble
L6
10
Polygon motor lock detection
U1
03
FAX board battery error (AL-2060 only)
U2
04
EEPROM read/write error (Serial communication
error)
11
Counter check sum error (EEPROM)
Main
code
Sub
code
Details of trouble
E1
00
Content IMC communication trouble
Detail
An abnormality occurs in communication
between the CPU and the IMC.
Cause
IMC abnormality
IMC memory defect/data abnormality
Check
and
remedy
Replace the MCU PWB with new one.
10
Content IMC trouble
Detail
An abnormality occurs in the IMC.
Cause
USB chip error/CODEC error on the IMC.
Check
and
remedy
Replace the MCU PWB with a new one.
13
Content IMC flash ROM error
Detail
An abnormality occurs in the IMC flash
ROM.
Cause
IMC abnormality
Check
and
remedy
Replace the MCU PWB with a new one.
If downloading of the program is abnormally
terminated, it may cause an error. Download
the program again to avoid this.
E1
81
Content IMC communication interface error (Parity)
Detail
A parity error occurs in communication
between the CPU and the IMC.
Cause
IMC abnormality
IMC memory defect/data abnormality
Check
and
remedy
Replace the MCU PWB with new one.
82
Content IMC communication interface error
(Overrun)
Detail
An overrun error occurs in communication
between the CPU and the IMC.
Cause
IMC abnormality
IMC memory defect/data abnormality.
Check
and
remedy
Replace the MCU PWB with new one.
84
Content IMC communication interface error
(Framing)
Detail
A framing error occurs in communication
between the CPU and the IMC.
Cause
IMC abnormality
IMC memory defect/data abnormality.
Check
and
remedy
Replace the MCU PWB with new one.
E7
01
Content Duplex model memory setup error, memory
not-detected error
Detail
The memory is not set properly or the
memory capacity is not set to the duplex
setup (6M).
Check
and
remedy
Set SIM 26-39 code number to 2.
02
Content LSU trouble
Detail
The BD signal from the LSU cannot be
detected in a certain cycle. (Always OFF or
always ON)
Cause
LSU connector or LSU harness defect or
disconnection
Polygon motor rotation abnormality
Laser beams are not generated.
MCU PWB abnormality.
Check
and
remedy
Check connection of the LSU connector.
Execute SIM 61-03 to check the LSU
operations.
Check that the polygon motor rotates
normally.
Check that the laser emitting diode
generates laser beams.
Replace the LSU unit.
Replace the MCU PWB.
10
Content Shading trouble (Black correction)
Detail
The CCD black scan level is abnormal when
the shading.
Cause
Improper connection of the CCD unit flat
cable
CCD unit abnormality
MCU PWB abnormality
Check
and
remedy
Check connection of the CCD unit flat cable.
Check the CCD unit.
Main
code
Sub
code
Details of trouble