EN-1
A
B
D
C
Trap
PIPING
Max. piping
length:A
Max. total piping length of all
unit
Min. piping
length:A
Max. height difference:
Chargeless Max.
piping length
Additional refrigerant
B
C
D
82 ft (25 m)
2 units:164 ft (50 m)
3 units, 4 units: 230 ft (70 m)
10 ft (3 m)
49 ft
(15 m)
49 ft
(15 m)
49 ft
(15 m)
164 ft (50 m)
0.16 oz/ft (15 g/m)
1. Standard piping length is 25 ft (7.6 m).
2. When the outdoor unit is placed at a higher level than the indoor unit, provide a trap near the hose’s lead-in port.
Use the refrigerant pipes shown in the table below.
Pipe size
Pipe thickness
Thermal insulation
Liquid side
1/4" (ø 6.35 mm)
0.03 inch (0.8 mm)
Thickness: 0.24 inch (6 mm) or thicker
Material: Polyethylene foam
Gas side
3/8" (ø 9.52 mm)
1/2" (ø 12.7 mm)
• The thermal insulation should cover both the gas and liquid pipes.
ACCESSORIES
ITEMS
Q’ty
ITEMS
Q’ty
ITEMS
Q’ty
1
Installation Manual
1
3
Drain tray
1
5
Reducer (1/2"
3/8")
2
2
Base pan cap
4
4
Drain joint
1
INSTALLATION DIAGRAM
3.3 ft (1000
mm) or more
1.3 ft (400
mm) or more
• Provide as much installation space as possible for
effi cient air-conditioning.
For installation work
1. Place the outdoor unit on a stable base.
2. Provided suffi cient space around the unit. It should also be
well ventilated.
3. The unit should not be exposed to strong wind nor splashed
with rain water.
4. Water drain from the unit should be let out without problem.
Lay a drain hose if required. In cold regions, installation of
the drain pipe is not advisable as freezing could result.
5. Keep TV sets, Radio and other related electronic appliances
at least 3.3 feet away from the unit.
6. Avoid locations exposed to machine oil vapor, salty air (facing
the seashore, for example), hot spring vapor sulfur gas, etc.
Such location can cause breakdown.
7. Avoid locations exposed to muddy water (along a road, for
example) or where the unit can be tampered with.
8. Select a location where the outgoing air or operating noise
cannot annoy others.
9. Keep the air outlet opening free of any obstacle. This could
affect the performance of the unit and create loud noises.
10.For colder climate areas, install the unit in a location not
affected by snow or ice falls (example: roof houses). Unit
should be installed minimum 10 inches (25 cm) from ground
level or follow your country’s average snowfall accumulation.
Carefully read and follow these instructions for smooth and trouble-free installation.
This manual describes the installation of outdoor unit only
For the installation of the indoor unit, see the installation manual accompanying indoor unit.
SAFETY PRECAUTIONS
• Tighten the fl are nut with a torque wrench according to the
specifi ed method.
If the fl are nut is tightened too hard, the fl are nut may be broken after a
long time and cause refrigerant gas leakage.
• When installing the unit, take care not to enter air substance other
than the specifi ed refrigerant(R410A) in the refrigerant cycle.
Otherwise, it will cause burst and injury as a result of abnormal high
pressure in the refrigerant cycle.
• Be sure to connect the refrigerant pipe before running the
compressor.
Otherwise, it will cause burst and injury as a result of abnormal high
pressure in the refrigerant cycle.
• Ground the unit.
Incomplete ground may cause electrical shock.
• Install a Ground Fault Interrupt (GFI) circuit breaker depending on
the installation location of the unit (such as highly humid areas).
If GFI breaker is not installed, it may cause electric shock.
• Arrange the drain hose to ensure smooth drainage.
Insuffi cient drainage may cause wetting of the room, furniture etc.
• This room air conditioner uses refrigerant R410A.
Use the pipe, fl are nut and tools exclusively for R410A.
NOTES ON LOCATIONS
1 ft (300
mm)
or more
• Installation must be made in accordance with the installation
manual by qualifi ed service personnel.
Incorrect work will cause electric shock, water leak, fi re.
• Be sure to use the attached accessories parts and specifi ed
parts for installation.
Use of other parts will cause electric shock, water leak, fi re, the unit
falling.
• The appliance shall be installed and wired in accordance with
National Electrical Code and by qualifi ed personnel only.
Wrong connection can cause overheating or fi re.
• After installation has complete, check that there is no leakage
of refrigerant gas.
If the refrigerant gas contact with fi re, it may generate toxic gas.
• Ventilate the room if refrigerant gas leaks during installation.
If the refrigerant gas contact with fi re, it may generate toxic gas.
• Use the specifi ed electrical cable.
Make sure the cable is secured in place and that the terminals are
free of any excess force from the cable. Otherwise overheating or
fi re may result.
• Form the cable so that the control box cover, the cord holder
and cable holder are not loose.
Otherwise overheating, fi re or electric shock may result.
Coating tape
(Commercially available)
Joint
Seal Ring
Flare nut
ENGLISH
1 ft (300
mm) or more