12. Insert the right side of the brush
bar in first by placing the end cap
down into the slot and then do the
same with the left side. Press
firmly to make sure that each end
is completely inserted.
13. Check to make sure that the belt is
centered on the agitator pulley and
that the brush bar turns.
14. Replace the belt cover.
15. Replace the power head cover
and turn the unit over carefully.
16. Replace the lower plate, screwing
in the four (4) outer screws first.
17. When screwing in the center
screw, hold the carpet height
adjustment knob from the outside
and screw in the last screw.
18. Once the lower plate is attached,
replace the base plate with the
four (4) screws.
5. Replace the new bulb by pushing
it in.
6. Replace the head light lens by
pushing it in so that it snaps back in
place.
Changing the Headlight Bulb
WARNING
:
To reduce the risk of
electric shock, the power cord must
be disconnected before removing the
dust cup, HEPA filter,changing the filters
or performing maintenance/trouble
shooting checks.
1. Turn unit “Off” and unplug from wall
outlet.
2. With a flat head screw driver, snap
off the lens cover by pressing down
on the two notches on the lens
cover. (Fig. 33)
3. Lift off the head light lens.
4. Remove the light bulb by pulling it
out carefully.
Notches
Fig. 33
OPERATING INSTRUCTIONS
10
6. Remove the belt cover (Fig. 32, #1)
7. Lift the right side of the brush bar first
and then lift the left hand side.
(Fig. 32 #2, #3)
8. Remove the brush bar from the power
head. (Fig. 32, #4)
9. Carefully remove any belt residue that
may exist in the belt area before
replacing with a new belt.
10. Remove the worn or broken belt from
the motor drive shaft.
11. Loop the new belt first over the motor
drive shaft and then over the agitator
pulley.
Fig. 32
5. With the unit still lying down, turn the
unit over and lift the power head
cover starting from the back of the
power head. (Fig. 31)
Fig. 31
Base Plate
Lower Plate
Fig. 30
PROBLEM POSSIBLE
CAUSE
POSSIBLE
SOLUTION
Cleaner Won’t
Run
1. Not properly plugged into
wall outlet.
2. No electricity in wall outlet.
3. On/Off switch not turned on.
4. Motor thermostat tripped.
5. Blown fuse/tripped breaker.
1.
Plug in firmly.
2.
Check fuse or breaker.
3.
Push on/off switch to “On” position.
4.
Reset motor thermostat.
5.
Reset circuit breaker or replace fuse.
Cleaner Won't
Pick Up
1.
Full or clogged dust cup.
2.
Wrong pile height setting.
3. Clogged
nozzle.
4.
Clogged dust inlet port.
5. Clogged
hose.
6. Broken
belt.
7.
Hose not inserted fully.
8. Dirty
filters.
9.
HEPA filter needs cleaning
or replacing.
10. HEPA filter frame needs
cleaning.
1.
Clean dust cup.
2. Adjust
setting.
3. Remove
obstruction.
4.
Remove power head cover and
remove obstruction.
5. Remove
obstruction.
6.
Replace belt.
7.
Push hose in securely.
8.
Clean / change filters.
9.
Clean or replace HEPA filter.
10. Clean HEPA filter frame.
Cleaner Picks
Up Moveable
Rugs Or
Pushes Too
Hard
1.
Wrong pile height setting.
1.
Adjust setting.
Agitator Does
Not Turn
1. Broken
belt.
2. Belt
installed
incorrectly.
1.
Replace belt.
2.
Check belt changing and agitator
cleaning.
Pet Hair Power
Brush Does Not
Rotate Or
Rotates Slowly
1.
Rotating brush, turbine or
elbow obstructed.
2. Belt
broken.
3. Hose
obstructed.
4. HEPA
filter
clogged.
1.
Clear obstructions.
2. Call
Customer
Service.
3. Clear
obstruction.
4.
Clean HEPA filter.
Air Flow
Restricted With
Attachment Use
1.
Attachment use restricts air
flow.
2.
New carpet debris clogging
air path.
1.
Check attachment.
2. Remove
obstruction.
PROBLEM SOLVING
This appliance was inspected thoroughly and was in good operating condition when it
was shipped from the factory. If a minor problem occurs, it usually can be solved quite
easily when the cause is found. Therefore, this checklist is provided for your
convenience.