TECHNICAL MANUAL
When the pulse is output to the connector pin specified while ESC p or DEL
DC4 is executed while this command is processed, this command is
ignored.
The printer executes this command upon receiving it.
With a serial interface model, this command is executed even when the
printer is off-line, the receive buffer is full, or there is an error status.
With a parallel interface model, this command cannot be executed when the
printer is busy. This command is executed even when the printer is off-line
or there is an error status when DIP switch 2-1 is on.
If print data includes the same character strings as this command, the
printer performs the same operation specified by this command. The user
must consider this.
This command should not be used within the data sequence of another
command that consists of 2 or more bytes.
This command is effective even when the printer is disabled with ESC =
(Select peripheral device).
[Reference]
ESC p
ESC FF
[Name]
Print data in page mode
[Format]
ASCII
ESC
FF
Hex
1B
0C
Decimal 27
12
[Description]
In page mode, prints all buffered data in the printable area collectively.
[Notes]
This command is enabled only in page mode.
After printing, the printer does not clear the buffered data, setting value
for ESC T and ESC W, and the position for buffering character data.
[Reference]
FF, ESC L, ESC S
ESC SP
n
[Name]
Set right-side character spacing
[Format]
ASCII
ESC
SP
n
Hex
1B
20
n
Decimal 27
32
n
[Range]
0≤
n
≤ 255