1
1 Function description
1
Function description
1.1
Usage
The correlator
SeCorr 08
permits to detect leakage points an
directly buried pressure line systems according to the correla-
tion principle. Sensitive microphones are used to record leakage
noise on accessible installations and fittings. These recordings
are wireless transmitted to the correlator.
SeCorr 08
calculates then the exact leakage position using the
Fast Fourier Transformation (FFT = mathematic algorithm).
Supplementary functions are available to improve e.g., the indi-
cation of leaks, to enter several pipe sections or to measure the
sound velocity.
The
RT 06
radio transmitter can be used to measure fully auto-
matically the input level of the microphone and to set the level
control of the amplifier to the optimum value. Characteristics and
parameters – such as the used microphone type, the charge state
of batteries and the amplifier setting – are wireless transmitted to
the correlator for further evaluation.
Note:
These operating instructions are based on soft
-
ware release 4.X, with „X“ standing for any number.
The currently installed software version of your
SeCorr 08
is displayed after switching on the device.
Future releases are subject to change!