23
8.0
Technical data
Serial no.
:
020 ...
.........
Calibration
:
methane CH
4
/ natural gas,
propane C
3
H
8
Measuring system
:
semiconductor sensor
Measuring range
:
0 - 1 vol.%
Test gas
:
1 vol.% methane or propane
Ex-protection (CENELEC)
- test institute
:
Physikalisch-Technische
Bundesanstalt, Braunschweig
- Certificate No.
:
Ex-96.ATEX.2167
- Classification
:
II 2 G EEx ib d IIC T3
Dimensions (W x H x D):
62 x 159 x 33 mm
Weight
:
480 g
Type of protection
:
IP 54
Operating time
:
max. 8 hours
Power supply
:
NiCd battery, rechargeable
Operating temperature :
- 10°C to + 40°Celsius
Storage temperature :
- 25°C to + 70°Celsius
Humidity range
:
5 - 90 % relative humidity
(non-condensing)
Pressure range
:
900 h Pa to 1100 h Pa
Type Design Number