4
Installation
Electrical installation
Compact Operating Instructions – MOVITRAC
®
LTP-B
23
4.1.7
Wiring diagram
WARNING
Danger of electric shock. Incorrect wiring can lead to dangerously high voltages.
Severe or fatal injuries.
•
Adhere to the following points.
In the following applications, always deactivate the brake in the AC and DC circuits:
•
All lifting applications.
•
Applications that require a quick brake response time.
Please note the following:
•
The following inverters with degree of protection IP66/NEMA 4X already have
openings for supply system, motor and control cables.
– 230 V: 0.75 – 5.5 kW
– 400 V: 0.75 – 11 kW
– 575 V: 0.75 – 15 kW
The following inverters with degree of protection IP55/NEMA 12K are equipped
with a metal entry board. The user can drill the cable entries according to the re-
quirements.
– 230 V: 5.5 – 75 kW
– 400 V: 11 – 160 kW
– 575 V: 15 – 110 kW
•
Connect the brake rectifier using a separate supply system cable.
•
Supply via the motor voltage is not permitted.
INFORMATION
In case of a new device, the terminal locations DC-, + (DC+) and BR are initially
provided with break-out covers. These must be broken out if required.
26879778/EN – 03/2021