6
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
PHE..B-A15-.1X0..B-00
60
6.10.13 X5002_3: Digital input – communication and control unit
Function
Digital input of communication and control unit
Connection type
M12, 5-pole, female, A-coded
Connection image
1
4
3
2
5
No.
Name
Function
1
+24V
DC 24 V output
2
DI05
Digital input 05
3
0V24
0V24 reference potential
4
DI04
Digital input 04
5
FE
Equipotential bonding / functional earth
6.10.14 X5002_4: Digital input – communication and control unit
Function
Digital input of communication and control unit
Connection type
M12, 5-pole, female, A-coded
Connection image
1
4
3
2
5
No.
Name
Function
1
+24V
DC 24 V output
2
DI07
Digital input 07
3
0V24
0V24 reference potential
4
DI06
Digital input 06
5
FE
Equipotential bonding / functional earth
23576855/EN – 10/2017