5
Mechanical installation
Installation
Operating Instructions – MOVIPRO
®
PHE..B-A15-.1X0..B-00
31
5.5.1
Fixed angle brackets
The following figure shows the main mounting elements and dimensions:
1
3
0
[4]
[4]
400.
1
377.1
[2]
[1]
[2]
[3]
9007211191020939
[1]
Mounting surface
[2]
Angle bracket
[3]
Device
[4]
Tapped holes
Mounting angle bracket
To mount the angle brackets, use the EMS mounting kit (part number 28218248) with:
ü
2 x angle bracket
ü
4 × M5 × 16 screw
1. Mount the angle brackets to the connection sides of the device with the M5 screws
via the available tapped holes on the housing.
Mounting the device
1. Refer to the dimension drawing for the distances regarding the boreholes for
mounting the angle bracket.
2. Mark the boreholes at the installation location.
3. Cut 2 M5 threads at the marked locations on each side.
4. Use suitable locking devices, e.g. lock washers according to DIN 7980 and wash-
ers according to DIN EN ISO 7090.
5. Mount the device on the angle brackets with 2 suitable M5 screws with the re-
quired length on each side, e.g. cap screws according to DIN EN ISO 4762.
5.5.2
Tapped holes on the rear of the device
The device has 4 tapped holes on the rear of the device. Refer to the dimension draw-
ing in chapter "Technical data" (→
82) for information on the dimensions for mount-
ing using tapped holes.
23576855/EN – 10/2017