6
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
PHE..B-A15-.1X0..B-00
47
No.
Name
Function
1
+R
Brake resistor (+)
2
-R
Brake resistor (-)
3
PE
PE connection
4
M
Message rail connection
5
L
X/M
Line connection phase X/jumper to signal contact con-
trol
This phase is used for the signal output.
6
L
Y
Line connection phase Y
7
L
Z
Line connection phase Z
8
C2/n.c.
Control input C2 (for device variant PHE..B-..-.1X0.2..)/
Not assigned
9
C1
Control input C1
Connection recommendation
INFORMATION
Phase L1, phase L2 or phase L3 can be connected to the control input C1 independ-
ent of phase L
X/M
. For further information, refer to chapter "Technical data" (→
82).
The phase that is connected to LX/M is output at the signal output. Select the connec-
tion assignment from the following recommendations depending on the desired signal
phase:
L
X/M
L
Y
L
Z
L1
L2
L3
L2
L3
L1
L3
L1
L2
23576855/EN – 10/2017