![SEW-Eurodrive INTERBUS UFI11A Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/sew-eurodrive/interbus-ufi11a/interbus-ufi11a_manual_1250336055.webp)
Manual – Fieldbus Interface INTERBUS UFI11A
55
9
Application examples
9.6
Writing of UFI11A or drive parameters via object 8288
The UFI offers a special parameter access via the object 8288 "variable data channel
with acyclical routing" for the universal write access to all data of the UFI or a drive in-
verter connected to the UFI (parameters, IPOS variables, IPOS program code, etc.).
The following description is the mechanism that can be used to change IPOS variables
or other variables via the parameter channel. The "variable data channel with acyclical
routing“ is available via index 8288 dez (2060 hex).
Example
Writing the value 74565 of the IPOS variable H0 = Index 11000 dez (2AF8 hex). The
value 74565 dez (0001 2345 hex) has to be written to the drive inverter with SBus
address 1.
After sending this service, you will receive the "Write_Confirmation." You can once again
use the return codes for the evaluation of a negative message.
Word
Meaning
Coding (hex)
1
Command_Code = Write_Request
00 82
2
Parameter_Count
00 09
3
Invoke_ID
Comm._Reference
00 02
4
Index = 8288
20 60
5
Subindex
Length
00 0C
6
Data[1] = Subkanal
Data[2] = Subadresse
01 01
7
Data[3] = Frametyp
Data[4] = Datenlänge
86 08
8
Data[5] = Verwaltung
Data[6] = Reserviert
32 00
9
Data[7] = Index High
Data[8] = Index Low
2A F8
10
Data[9]
Data[10]
00 01
11
Data[11]
Data[12]
23 45
Bits
15 ... 8
7 ... 0