Communication
70
Communication
16
240
_10
0300
05/EN - 0
2/2
022
Operating manual [27779165/EN] - EMS modular controls
16.1.2
Interface Description
The following description refers to transmission via PROFINET
(PROFINET IO between PLC and the MAXO-RG-BSx module).
PLC data to EMS modular control
Byte Bit
Description
0
0 ... 7
Vehicle speed setting LOW byte
1
0 ... 7
Vehicle speed setting HIGH byte
2
0
1 ... Emergency stop
1
1 ... Open brake
2
1 ... Speed controller Enable (only axle 1)
3
Acceleration bit 0
4
Acceleration bit 1
5
Deceleration bit 0
6
Deceleration bit 1
7
Reserve
3
0 ... 7
Position setting LOW byte
4
0 ... 7
Position setting MIDDLE byte
5
0 ... 7
Position setting HIGH byte
6
0
1 ... DOUT 4 main flange ON
1
0 ... forward; 1 ... back
2
1 ... Fault acknowledgment
3
1 ... Deactivate stop configuration
4
1 ... Deactivate BCR fault (only axle 1)
5
1 ... DOUT 1 main flange ON
6
1 ... DOUT 2 main flange ON
7
1 ... DOUT 3 main flange ON
7
0
Axle identification bit 0
1
Axle identification bit 1
2
Axle 1 stop/speed = 0
3
Axle 2 stop/speed = 0
4
Axle 3 stop/speed = 0
5
Axle 4 stop/speed = 0
6
Stop conf. Variant bit 0
7
Stop conf. Variant bit 1