Connections
56
Connections
13
240
_10
0300
05/EN - 0
2/2
022
Operating manual [27779165/EN] - EMS modular controls
Connection X60/X61
Fig. 13-13 Contact assignment connections X60 / X61
Specifica-
tion
Description
Note
Function
STO1 interface
-
Designation
X60
-
Connection
type
M12, 4-pin, A coded, socket
Coding tab at position "11 o'clock”
Contact
Function
Description
1
STO1-OUT
STO1 output
2
STO1-
STO1 input
3
STO1-GND
STO1 mass
4
STO1+
STO1 input +
Specifica-
tion
Description
Note
Function
STO2 interface
-
Designation
X61
-
Connection
type
M12, 4-pin, A coded, socket
Coding tab at position "11 o'clock”
Contact
Function
Description
1
STO2-OUT
STO output
2
STO2-
STO2 input
3
STO2-GND
STO2 mass
4
STO2+
STO2 input +