6
Appendix
Description of the access points
Manual – ECDriveS
®
44
Process
data word
[PO]
Data
type
Designation
Bytewise
notation
[byte.bit]
Wordwise
notation
[word.bit]
Description
8
Int
ReleaseControlUpstream
16.0
16.7
8.0
8.15
Used to release material being conveyed that was accu-
mulated in the upstream zone of the fieldbus controller.
The Release command is dominant in relation to the Ac-
cumulate command.
Flank
Flank control. The values in this process data word can
be selected freely. The control is activated as soon as a
value is changed.
Example:
Flank 4-->5 = Release
Flank 5-->6 = Release
17.0
17.7
9
Int
ReleaseControlDownstream
18.0
18.7
9.0
9.15
Used to release material being conveyed that was accu-
mulated in the downstream zone of the fieldbus control-
ler. The Release command is dominant in relation to the
Accumulate command.
Refer to ReleaseControlUpstream for a description
19.0
19.7
10
Word
InductControlState
20.0
20.7
10.0
10.15
Upstream Wakeup:
Wakeup of the upstream zone
when the material being conveyed is taken over by a
system section that is not controlled with ECDriveS
®
.
Value 0x04
: Enabling of upstream zone
Value 0x01
: Stop of upstream zone
21.0
21.7
11
Word
DischargeControlState
22.0
22.7
11.0
11.15
Downstream Lane Full:
Control of the downstream
zone when the material being conveyed is taken over by
a system section that is not controlled with ECDriveS
®
.
Value 0x05
: Jam product downstream
Value 0x01
: Release product downstream
23.0
23.7
12
Dword
ModuleInductTrackingOnIn-
ductSide
24.0
24.7
12.0
12.15
If material being conveyed is taken over from a system
section that is not controlled with ECDriveS
®
by Induct-
ControlStage, the corresponding 32 bit tracking code
can be written in ModuleInductTrackingOnInductSide.
The tracking for this material being conveyed is started
at the same time
25.0
25.7
13
26.0
26.7
13.0
13.15
27.0
27.7
14
Dword
ModuleInductTrackingOnDis-
chargeSide
28.0
28.7
14.0
14.15
Description corresponds to ModuleInductTrackingOnIn-
ductSide, but applies to the takeover of material being
conveyed when the direction of flow is opposite to the
configured direction of flow. Example: Material being
conveyed was transfered by DischargeControlStage to
an adjacent system section. The direction of flow is then
changed and the material being conveyed is taken over
by this zone
29.0
29.7
15
30.0
30.7
15.0
15.15
31.0
31.7
16
Word
ClearMotorError
32.0
32.7
16.0
16.15
Error reset
Value 0x01
: Reset
Value 0x00
: Clear bits
33.0
33.7
17
Word
Res.
34.0
34.7
17.0
17.15
35.0
35.7
18
Word
Res.
36.0
36.7
18.0
18.15
37.0
37.7