data word
[PI]
Data
type
Designation
Bytewise
notation
[byte.bit]
Wordwise
notation
[word.bit]
Description
Bool
14.2
7.2
ShortCircuit
: Motor short circuit
Bool
14.3
7.3
MDRNotConnected:
No motor is connected to the mo-
tor port
Bool
14.4
7.4
Overload
: Overload detected. Speed lowered to <10%
of the setpoint speed due to the overload
Bool
14.5
7.5
Stalled
: Motor blockade detected
Bool
14.6
7.6
MDRBadHall:
Hall sensor fault
Bool
14.7
7.7
MDRNotUsed
: Zone was not configured in ZPA
Bool
15.0
7.8
MDRStatus Bit1:
Description of the 2-bit coded
statuses
Bool
15.1
7.9
MDRStatus Bit2
: Description of the 2-bit coded
statuses
Bool
15.2
7.10
MDRinDOmode
: Motor port is connected to the digital
I/O mode
15.3
15.5
7.11
7.13
Res.
Bool
15.6
7.14
OverVoltage:
Overvoltage fault
Bool
15.7
7.15
LowVoltage
: Undervoltage fault
8
Int
RightCurrent (RightM-
DRStatus)
16.0
16.7
8.0
8.15
Right motor roller current
17.0
17.7
9
Int
RightFreq (RightMDRStatus)
18.0
18.7
9.0
9.15
Frequency at the Hall effect sensor on the right motor
roller
19.0
19.7
10
Byte
RightCalcTemp (RightM-
DRStatus)
20.0
20.7
10.0
10.15
Calculated temperature of the right motor roller
Byte
ModuleTemp_1 (RightM-
DRStatus)
21.0
21.7
Temperature of the power section of the right drive axis,
measured in °C
11
Struct
Bool
RightMDRDiagnostic (RightM-
DRStatus)
22.0
11.0
Overheat
: Overtemperature fault
Bool
22.1
11.1
MaxTorque:
Motor at current limit
Bool
22.2
11.2
ShortCircuit
: Motor short circuit
Bool
22.3
11.3
MDRNotConnected:
No motor is connected to the mo-
tor port
Bool
22.4
11.4
Overload
: Overload detected
Bool
22.5
11.5
Stalled
: Motor blockade detected
Bool
22.6
11.6
MDRBadHall:
Hall sensor fault
Bool
22.7
11.7
MDRNotUsed
: Zone was not configured in ZPA
Bool
23.0
11.8
MDRStatus Bit1
: Description of the 2-bit coded
statuses
Bool
23.1
11.9
MDRStatus Bit2
: Description of the 2-bit coded
statuses
Bool
23.2
11.10
MDRinDOmode
: Motor port is connected to the digital
I/O mode
23.3
23.5
11.11
11.13
Res.
Bool
23.6
11.14
OverVoltage
: Overvoltage fault
Bool
23.7
11.15
LowVoltage
: Undervoltage fault
12
Struct
LeftMDR_DIOstatus
24.0
24.3
12.0
12.3
Res.
Bool
24.4
12.4
ShortCircuit
: Short circuit b24 V and Pin2/3/4
24.5
24.7
12.5
12.7
Res.
25.0
25.7
12.8
12.15
Res.
25938274/EN – 01/2019