6
Appendix
Description of the access points
Manual – ECDriveS
®
41
Process
data word
[PI]
Data
type
Designation
Bytewise
notation
[byte.bit]
Wordwise
notation
[word.bit]
Description
6
Struct
Bool
Diagnostic
12.0
6.0
LeftMDR_Overheat
: Overtemperature fault in left motor
roller
Bool
12.1
6.1
LeftMDR_MaxTorque
: Motor at current limit
Bool
12.2
6.2
LeftMDR_Short
: Motor short circuit
Bool
12.3
6.3
LeftMDR_MDR_NotConn:
No motor is connected to
the motor port
Bool
12.4
6.4
LeftMDR_Overload
: Overload detected
Bool
12.5
6.5
LeftMDR_Stalled
: Motor blockade detected
Bool
12.6
6.6
LeftMDR_BadHall:
Hall sensor fault
Bool
12.7
6.7
LeftMDR_NotUsed
: Zone was not configured in ZPA
Bool
13.0
6.8
Res.
Bool
13.1
6.9
Res.
Bool
13.2
6.10
OverVoltage
: Overvoltage error on left DC-AC inverter
Bool
13.3
6.11
LeftMDR_AnyErr
: Global error bit, left motor roller. Bits
0 – 10 indicate specific error
Bool
13.4
6.12
ConnectionsNotOK
: Faulty Ethernet connection
Bool
13.5
6.13
UpstreamJamErr:
Jam error in upstream zone
Bool
13.6
6.14
LeftSensLowGain:
Error in the left sensor
Bool
13.7
6.15
LowVoltage:
Undervoltage error (supply voltage <
18 V)
7
Struct
Bool
14.0
7.0
RightMDR_Overheat
: Overtemperature error in the
right motor roller
Bool
14.1
7.1
RightMDR_MaxTorque
: Motor at current limit
Bool
14.2
7.2
RightMDR_Short
: Motor short circuit
Bool
14.3
7.3
RightMDR_MDR_NotConn:
No motor is connected to
the motor port
Bool
14.4
7.4
RightMDR_Overload
: Overload detected
Bool
14.5
7.5
RightMDR_Stalled:
Motor blockade detected
Bool
14.6
7.6
RightMDR_BadHall:
Hall sensor fault
Bool
14.7
7.7
LeftMDR_NotUsed
: Zone was not configured in ZPA
Bool
15.0
7.8
Res.
Bool
15.1
7.9
Res.
Bool
15.2
7.10
OverVoltage
: Overvoltage error on right DC-AC inverter
Bool
15.3
7.11
RightMDR_AnyErr
: Global error bit, right motor roller.
Bits 0 – 10 indicate specific error
Bool
15.4
7.12
Res.
Bool
15.5
7.13
DownstreamJamErr:
Jam error in downstream zone
Bool
15.6
7.14
RightSensLowGain:
Error in the right sensor
Bool
15.7
7.15
LowVoltage:
Undervoltage error (supply voltage <
18 V)
8
Dword
TrackingUpstreamZone
16.0
16.7
8.0
8.15
Read ZPA tracking data of the upstream zone
17.0
17.7
9
18.0
18.7
9.0
9.15
19.0
19.7
10
Dword
TrackingDownstreamZone
20.0
20.7
10.0
10.15
Read ZPA tracking data of the downstream zone
21.0
21.7
11
22.0
22.7
11.0
11.15
23.0
23.7
25938274/EN – 01/2019