4
Installation
Mechanical installation
Operating instructions – ECDriveS
®
18
Continue with cable side:
[1]
[2]
19844223243
[1]
M12 flange nut
[2]
Axis
5. Screw the flange nut [1] from outside onto the axis [2] on the cable side.
6. Grip axis [2] from inside with a suitable tool and tighten the flange nut [1] with a
tightening torque of 50 Nm.
Continue with opposite side:
7. Grip axis journal [2] from inside on the opposite side with a suitable tool and
tighten the screw with spur-cut teeth [1] from outside with a tightening torque of
10 – 14 Nm.
Design B
•
Cable side: M12×1.25 on 11 mm hexagon
•
On the opposite side: smooth 11 mm spring-loaded hexagon axis
•
Mounting hole position: M12 nut
Proceed as follows:
Start at the cable side:
1. Guide the connector and the cable through the profile hole on the cable side.
2. Insert the axis into the profile hole on the cable side.
28507088/EN – 11/2018