5
Startup
Setting the DIP switches
Operating instructions – ECDriveS
®
28
5.2.2
DIP switches 7 to 10: Roller acceleration/deceleration
S7
S8
S9
S10
acceleration/deceleration time in s
-
-
-
-
0.05
-
-
-
x
0.1
-
-
x
-
0.2
-
-
x
x
0.3
-
x
-
-
0.4
-
x
-
x
0.5
-
x
x
-
0.6
-
x
x
x
0.7
x
-
-
-
0.8
x
-
-
x
1
x
-
x
-
1.2
x
-
x
x
1.4
x
x
-
-
1.6
x
x
-
x
1.8
x
x
x
-
2
x
x
x
x
2.5
x = ON
- = OFF
Notice: The specified time in seconds applies to the acceleration and to the decelera-
tion.
28507088/EN – 11/2018